INSTALLING THE DUCT PLENUMS

STEP 1:

Remove the filter grill from the unit by unscrewing the screws that hold it in place.

STEP 2:

Move the Ducting Adapters into place

STEP 3:

Screw the ducting adapters into place using the supplied screws.

Page 24

EXti 110111

Image 26
Contents Extreme 5000 Page Table of Contents Quick Reference Guide Front / Side ViewFully Ducted Front / Side View 8000 / 8000 Rear / Side View Compressor Access Panel Standard Controller Layout Model Unit SpecificationsFAN Speed Reference Low Med HighIntroduction Receiving & Inspecting the Unit Review the Packing Slip to Verify ContentsCheck the Box for the following contents 5000 Receiving and Inspecting the UnitQuick Start Guide Vapor Barrier Preparing the Wine CellarInsulation Door and Door Seal Mounting the UnitUnobstructed Airflow Ventilation Air Intake Cellar Wall Ambient Temperature FactorUsing any other ducting system will void the warranty Exhaust FanElectrical Inlets PRE-INSTALLATIONElectrical Needs Preparing the Installation Location Minimum Tools NeededSingle Piece Mounting Bracket Preparing the System for InstallationMounting Bracket Installation Applying Insulation Tape8000 Mounting FlangesFlush Installation Exterior Grille InstallationNon-Flush Installation Optional Exterior Grille8000 Back of Unit THROUGH-THE-WALL InstallationInstalling the System General Duct Recommendations Ducting OverviewUse of Ductwork Location of Supply and Return GrillesThree-Quarter Duct Configuration Wine Cellar Ducting ConfigurationsHalf Duct Configuration Wine Cellar Adjacent RoomFully Ducted Attic Mounted SystemInstalling the Duct Plenums Remote Controller Installation Mounting Bracket Condensation Drain Line Tube Failure to install the drain line voids the warrantyDrain Line Drain LineLiquid Measuring Thermostat System Liquid Measuring Thermostat SystemSelf-Calibrating Probe To Use the thermostat57/57 Multi FAN Speed Control59/59 60/61 System Operation Up and Down Button/Symbol Normal FunctionsStandard Controller Functions ArrowsAlarm Anti-FrostPage Standard Remote Controller Functions Button Normal FunctionsCheck Evaporator Probe connection at green terminal block on Cpsm Mode Remote Wire Schematic Maintenance Schedule Unit does not run/power up Possible Cause Solution Cellar Temperature is to Warm Possible Cause SolutionPossible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Compressor short cycles Possible Cause SolutionTechnical Assistance Accessories for Cooling UnitsContact WhisperKOOL Customer Service Condensate Pump KitInstallation Terms and Conditions WhisperKOOL Cooling SystemProduct Installation Requirements Model Serial NumberA Installed by Date Sales and USE TAXPage Page WhisperKOOL