WhisperKool 5000 owner manual Compressor Access Panel

Page 7

QUICK REFERENCE GUIDE

8000 - Front / Side View

Grille w/Filter

Controller w/Remote Box

Compressor

Access Panel

Control Panel

(see page 14 for details)

Bottle Probe

Fan Speed Control

8000 Fully Ducted - Front / Side View

Exhaust Plenum

Supply Plenum

Return Plenum

Controller w/Remote Box

Intake Plenum

Compressor Access Panel

Control Panel

(see page 14 for details)

Bottle Probe

Fan Speed Control

Page 5

Image 7
Contents Extreme 5000 Page Table of Contents Front / Side View Quick Reference GuideFully Ducted Front / Side View 8000 / 8000 Rear / Side View Compressor Access Panel Standard Controller Layout Low Med High Unit SpecificationsFAN Speed Reference ModelIntroduction Receiving and Inspecting the Unit Review the Packing Slip to Verify ContentsCheck the Box for the following contents 5000 Receiving & Inspecting the UnitQuick Start Guide Insulation Preparing the Wine CellarVapor Barrier Unobstructed Airflow Mounting the UnitDoor and Door Seal Exhaust Fan Air Intake Cellar Wall Ambient Temperature FactorUsing any other ducting system will void the warranty VentilationElectrical Needs PRE-INSTALLATIONElectrical Inlets Minimum Tools Needed Preparing the Installation LocationApplying Insulation Tape Preparing the System for InstallationMounting Bracket Installation Single Piece Mounting BracketMounting Flanges 8000Optional Exterior Grille Exterior Grille InstallationNon-Flush Installation Flush Installation8000 Installing the System THROUGH-THE-WALL InstallationBack of Unit Location of Supply and Return Grilles Ducting OverviewUse of Ductwork General Duct RecommendationsAdjacent Room Ducting ConfigurationsHalf Duct Configuration Wine Cellar Three-Quarter Duct Configuration Wine CellarAttic Mounted System Fully DuctedInstalling the Duct Plenums Remote Controller Installation Mounting Bracket Drain Line Failure to install the drain line voids the warrantyDrain Line Condensation Drain Line TubeTo Use the thermostat Liquid Measuring Thermostat SystemSelf-Calibrating Probe Liquid Measuring Thermostat System59/59 60/61 Multi FAN Speed Control57/57 System Operation Arrows Button/Symbol Normal FunctionsStandard Controller Functions Up and DownAnti-Frost AlarmPage Standard Button Normal Functions Remote Controller FunctionsCheck Evaporator Probe connection at green terminal block on Cpsm Mode  Remote Wire SchematicMaintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Unit does not run/power up Possible Cause SolutionCompressor short cycles Possible Cause Solution Unit leaks water Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Possible Cause SolutionCondensate Pump Kit Accessories for Cooling UnitsContact WhisperKOOL Customer Service Technical AssistanceWhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Model Serial NumberA Installed by DatePage Page WhisperKOOL