WhisperKool 5000 owner manual 8000

Page 21

OPTIONAL EXTERIOR GRILLE

8000 / 8000

Exterior Grille Installation

The exterior grille is required on all installations where the exhaust side of the unit is exposed to the outside of the dwelling (i.e. rain and weather).

Non-Flush Installation

Install the system according to the standard through-the-wall procedure. After the system is installed, remove the exhaust side filter grille and place the exterior grille over the system. Line up the screw holes on the top, bottom, and sides. Use the supplied (8) self tapping screws to fasten the grille to the unit.

Flush Installation

This installation is slightly different because you are utilizing the same holes for both the mounting flanges and exte- rior grille.

1.Slide the exterior grille onto the system and align the screw holes of the exterior grill with the screw locations on the system.

2.Place the top mounting flange and use the supplied self tapping screws to fasten the flange and grille to the system.

3.Repeat step 2 on the bottom and sides of the system.

4.Continue through-the-wall installation.

It is required to use self tapping screws provided. Do not drill screws into unit.

Non-Flush Installation

Flush Installation

Page 19

Image 21
Contents Extreme 5000 Page Table of Contents Front / Side View Quick Reference GuideFully Ducted Front / Side View 8000 / 8000 Rear / Side View Compressor Access Panel Standard Controller Layout FAN Speed Reference Unit SpecificationsModel Low Med HighIntroduction Check the Box for the following contents 5000 Review the Packing Slip to Verify ContentsReceiving & Inspecting the Unit Receiving and Inspecting the UnitQuick Start Guide Preparing the Wine Cellar InsulationVapor Barrier Mounting the Unit Unobstructed AirflowDoor and Door Seal Using any other ducting system will void the warranty Air Intake Cellar Wall Ambient Temperature FactorVentilation Exhaust FanPRE-INSTALLATION Electrical NeedsElectrical Inlets Minimum Tools Needed Preparing the Installation LocationMounting Bracket Installation Preparing the System for InstallationSingle Piece Mounting Bracket Applying Insulation TapeMounting Flanges 8000Non-Flush Installation Exterior Grille InstallationFlush Installation Optional Exterior Grille8000 THROUGH-THE-WALL Installation Installing the SystemBack of Unit Use of Ductwork Ducting OverviewGeneral Duct Recommendations Location of Supply and Return GrillesHalf Duct Configuration Wine Cellar Ducting ConfigurationsThree-Quarter Duct Configuration Wine Cellar Adjacent RoomAttic Mounted System Fully DuctedInstalling the Duct Plenums Remote Controller Installation Mounting Bracket Drain Line Failure to install the drain line voids the warrantyCondensation Drain Line Tube Drain LineSelf-Calibrating Probe Liquid Measuring Thermostat SystemLiquid Measuring Thermostat System To Use the thermostatMulti FAN Speed Control 59/59 60/6157/57 System Operation Standard Controller Functions Button/Symbol Normal FunctionsUp and Down ArrowsAnti-Frost AlarmPage Standard Button Normal Functions Remote Controller FunctionsCheck Evaporator Probe connection at green terminal block on Cpsm Mode  Remote Wire SchematicMaintenance Schedule Cellar Temperature is to Warm Possible Cause Solution Unit does not run/power up Possible Cause SolutionUnit runs but does not cool Possible Cause Solution Unit leaks water Possible Cause SolutionPossible Cause Solution Compressor short cycles Possible Cause SolutionContact WhisperKOOL Customer Service Accessories for Cooling UnitsTechnical Assistance Condensate Pump KitWhisperKOOL Cooling System Installation Terms and ConditionsProduct Installation Requirements Sales and USE TAX Model Serial NumberA Installed by DatePage Page WhisperKOOL