MODEL 450H OZONE MONITOR
Printed 05/15/06
SAFETY MESSAGES
3.0 SETUP MODE
TABLE OF CONTENTS
4.0 MAINTENANCE
5.0 ADJUSTMENTS
5.3 A/D - D/A CALIBRATION PROCEDURE…
APPENDIX A - ELECTRICAL SCHEMATIC INDEX
5.4 CURRENT LOOP CALIBRATION
FIGURES
TABLE 1.1 DIGITAL OUTPUTS
TABLES
TABLE 1.2 CONTROL INPUTS
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
1.1Preface
1.0INTRODUCTION
ADVANCED POLLUTION INSTRUMENTATION DIVISION
1.2 WARRANTY POLICY
02024c
COVERAGE
1.3 Principle of Operation
Page
1.5 Installation 19” Rack Mount Enclosure
1.4 Specifications
Page
5.If the M450H has been configured with the auto-zerovalve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line
1.6 Installation NEMA 4X Wall Mount Enclosure
ozone
FIGURE 1.1 - NEMA 4X MOUNTING HOLE DIMENSIONS
FIGURE 1.2 - NEMA 4X ELECTRICAL POWER CONNECTIONS
FIGURE 1.3 - NEMA 4X PNEUMATIC CONNECTIONS
1.6Electrical I/O Connections
FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS
1.6.1Analog Output
1.6.2 Relay Outputs
1.6.4 Control Inputs
FIGURE 1.5 - CONNECTING DIGITAL OUTPUTS
Output
Description
Input
1.6.5 RS232 Output
CONTROL INPUTS
Zero Calibrate
FIGURE 1.7 - M450H PNEUMATIC BLOCK DIAGRAM
FIGURE 1.6 - NEMA4X ASSEMBLY LAYOUT
U V L A M P M O T H E R B V / F C P U A C L I N E
D C P O W E R SO
POWER SUPPLY MODULE
Figure 1.8 - 19” Rack Assembly Layout
1.7 Operation verification
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
1.8 Options
1.8.5 Flow Switch
1.8.1 Auto-ZeroOption
1.8.2 Isolated Current Output 4-20mAor 2-20mA
2.1.2 Concentration Alarms
2.1Key features
2.1.4 E2 ROM backup of software configuration
2.0OPERATION
2.2.1 Front panel display fields
2.2 Front Panel Display
FIGURE 2.1 - MODEL 450H FRONT PANEL
Mode Field
Test Message
Message/Test Measurement Field
TEST MEASUREMENTS
Warning Message
2.2.2 Status LED’s
2.3 Software Operation
2.3.1 Main Menu
State
FIGURE 2.3 - ALARM STATUS MENU
2.3.3 Alarm Status Menu
Clearing Alarms
Audible Beeper
Page
FIGURE 3.1 - SETUP MENU
3.0 SETUP MODE
3.2 Setting the Concentration Units UNIT
3.1 Setting the Concentration Alarms ALRM
3.3 Setting the time-of-dayand date CLK
HI ALARM OFF
3.4 Setting the RS-232baud rate COMM
0 LATCH_ALARMS
3.5 Setup variables VARS
1 ALARM BEEPER
3 AZERO ENABLE
10 TPC ENABLE
8 GAS MOLECULAR WEIGHT
7 AZERO HOLD OFF
9 CONCENTRATION RANGE
3.5.1Zero Calibration
3.5Diagnostics DIAG
3.5.2 D/A Calibration
3.5.3 Analog Output
4.2Cleaning Exterior Surfaces of the M450H
4.0Maintenance
4.3 Cleaning the Optical Cell
Filter Replacement Procedure
4.4 Degree of Protection
FIGURE 4.1 MEASUREMENT CELL DISASSEMBLY
Switch Settings
5.0 ADJUSTMENTS
5.1 Calibration
5.2Changing the analog output range
1.Press SETUP-DIAG
5.3 A/D - D/A Calibration Procedure
FIGURE 4.2- ANALOG OUTPUT JUMPERS
5.4 Current Loop Calibration
zero point can be adjusted anywhere between 0 and 4 milliamps. Press ENTR when you have reached the desired zero point as measured by your test meter
APPENDIX A - SOFTWARE MENU TREE
Page
DESCRIPTION
APPENDIX B - SPARE PARTS LIST
Page
Drawing Number
APPENDIX C - ELECTRICAL SCHEMATIC INDEX
Title
Related pages
NetBIOS over IP Troubleshooting for Xerox 7345
Specifications for RCA WSP200
Error message Out of paper. Load paper then press OK for HP D7100
Application Diagrams for Extron electronic IPL T SF2
Special care when heating dishes or drinks that for Samsung ME73A/XEE
Reverse the above procedure to install a memory module for HP DV8000
Parts List for Coleman 5459
Code List for GE RM94903
JourneyMan Lifetime Warranty for Desa HD-9260
Setting the Playback Mode for Marantz PMD330
What settings can I customize in the
Aquacal T135 heat pump
?
Top
Page
Image
Contents