Teledyne 450H instruction manual Appendix B - Spare Parts List, Description

Page 47
APPENDIX B – SPARE PARTS LIST

APPENDIX B – SPARE PARTS LIST

PART NO.

DESCRIPTION

030360000

Teledyne API Model 450H Spare Parts List

002760451

CPU Board (450H)

005140300

V/F Board

007040000

Keyboard

007280000

Display

015610000

I2C/Sub Mux, M450

023480000

Filter PAD, Ozone Scrubber

023620100

Rear Panel PCA, Single Channel

023900000

UV Lamp Supply

024040000

Power Supply Module, M450

024740000

Tubing: 6’, 1/4” CLR FEP

025710000

Measure Detector Preamp

026490000

Heater, Cartridge, 120V, 20W

026540000

Reference Detector Preamp

027010000

Sensor Assembly, M450

027020000

Assy, Auto Zero Valve

027030000

Assy, Needle Valve, Kalrez Seals

028260000

Manual, Instruction, M450H

028320000

Assy, Sample Filter, 25mm

028330000

Assy, Oxone Killer w/o Flow Switch

028340000

Assy, Thermistor, Cell & Lamp

028350000

Assy, UV Lamp (M450H)

028510000

Kit, 25mm Glass Filters (50)

FM0000016

Flowmeter, 0-2 LPM

HW0000036

TFE Thread Tape (48 FT)

IC0000055

Isolated Current Loop Driver, AD1B22N

OP0000019

Window Sapphire 3/4" x 2mm

OR0000070

Oring, Sensor Assy M450H

OR0000071

Oring,Sensor Assy M450H

OR0000072

Oring, Sensor Assy M450H

PS0000011

Switching PS, 40W, 5V,

PS0000012

Switching PS, 20W

PU0000020

Pump, 115V 50/60 Hz

PU0000022

Pump Rebuild Kit, KNF Model #NO5ATI

P/N 02826B1 Teledyne API Model 450H O3 Monitor Instruction Manual - Page 47

Image 47
Contents Printed 05/15/06 MODEL 450H OZONE MONITOREMAIL api-sales@teledyne.com SAFETY MESSAGES 5.0 ADJUSTMENTS TABLE OF CONTENTS3.0 SETUP MODE 4.0 MAINTENANCE5.4 CURRENT LOOP CALIBRATION APPENDIX A - ELECTRICAL SCHEMATIC INDEX5.3 A/D - D/A CALIBRATION PROCEDURE… FIGURES TABLE 1.3 FINAL TEST AND CALIBRATION VALUES TABLESTABLE 1.1 DIGITAL OUTPUTS TABLE 1.2 CONTROL INPUTS1.1Preface 1.0INTRODUCTIONCOVERAGE 1.2 WARRANTY POLICYADVANCED POLLUTION INSTRUMENTATION DIVISION 02024c1.3 Principle of Operation Page 1.5 Installation 19” Rack Mount Enclosure 1.4 SpecificationsPage 5.If the M450H has been configured with the auto-zerovalve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line 1.6 Installation NEMA 4X Wall Mount Enclosure ozone FIGURE 1.1 - NEMA 4X MOUNTING HOLE DIMENSIONS FIGURE 1.2 - NEMA 4X ELECTRICAL POWER CONNECTIONS FIGURE 1.3 - NEMA 4X PNEUMATIC CONNECTIONS 1.6.2 Relay Outputs FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS1.6Electrical I/O Connections 1.6.1Analog OutputDescription FIGURE 1.5 - CONNECTING DIGITAL OUTPUTS1.6.4 Control Inputs OutputZero Calibrate 1.6.5 RS232 OutputInput CONTROL INPUTSD C P O W E R SO FIGURE 1.6 - NEMA4X ASSEMBLY LAYOUTFIGURE 1.7 - M450H PNEUMATIC BLOCK DIAGRAM U V L A M P M O T H E R B V / F C P U A C L I N EPOWER SUPPLY MODULE Figure 1.8 - 19” Rack Assembly Layout1.7 Operation verification TABLE 1.3 FINAL TEST AND CALIBRATION VALUES 1.8.2 Isolated Current Output 4-20mAor 2-20mA 1.8.5 Flow Switch1.8 Options 1.8.1 Auto-ZeroOption2.0OPERATION 2.1Key features2.1.2 Concentration Alarms 2.1.4 E2 ROM backup of software configurationMode Field 2.2 Front Panel Display2.2.1 Front panel display fields FIGURE 2.1 - MODEL 450H FRONT PANELWarning Message Message/Test Measurement FieldTest Message TEST MEASUREMENTSState 2.3 Software Operation2.2.2 Status LED’s 2.3.1 Main MenuAudible Beeper 2.3.3 Alarm Status MenuFIGURE 2.3 - ALARM STATUS MENU Clearing AlarmsPage FIGURE 3.1 - SETUP MENU 3.0 SETUP MODEHI ALARM OFF 3.1 Setting the Concentration Alarms ALRM3.2 Setting the Concentration Units UNIT 3.3 Setting the time-of-dayand date CLK3.4 Setting the RS-232baud rate COMM 3 AZERO ENABLE 3.5 Setup variables VARS0 LATCH_ALARMS 1 ALARM BEEPER9 CONCENTRATION RANGE 8 GAS MOLECULAR WEIGHT10 TPC ENABLE 7 AZERO HOLD OFF3.5.3 Analog Output 3.5Diagnostics DIAG3.5.1Zero Calibration 3.5.2 D/A CalibrationFilter Replacement Procedure 4.0Maintenance4.2Cleaning Exterior Surfaces of the M450H 4.3 Cleaning the Optical Cell4.4 Degree of Protection FIGURE 4.1 MEASUREMENT CELL DISASSEMBLY5.2Changing the analog output range 5.0 ADJUSTMENTSSwitch Settings 5.1 CalibrationFIGURE 4.2- ANALOG OUTPUT JUMPERS 5.3 A/D - D/A Calibration Procedure1.Press SETUP-DIAG 5.4 Current Loop Calibration zero point can be adjusted anywhere between 0 and 4 milliamps. Press ENTR when you have reached the desired zero point as measured by your test meter APPENDIX A - SOFTWARE MENU TREE Page DESCRIPTION APPENDIX B - SPARE PARTS LISTPage Title APPENDIX C - ELECTRICAL SCHEMATIC INDEXDrawing Number