Teledyne
450H
instruction manual
Current Loop Calibration
Specs
Parts list
Concentration Alarms
Warranty
Maintenance
3.5Diagnostics DIAG
Setup Mode
Adjustments
Weight
Safety
Page 43
Page 42
Page 44
Image 43
Page 42
Page 44
Contents
EMAIL api-sales@teledyne.com
MODEL 450H OZONE MONITOR
Printed 05/15/06
SAFETY MESSAGES
5.0 ADJUSTMENTS
TABLE OF CONTENTS
3.0 SETUP MODE
4.0 MAINTENANCE
5.3 A/D - D/A CALIBRATION PROCEDURE…
APPENDIX A - ELECTRICAL SCHEMATIC INDEX
5.4 CURRENT LOOP CALIBRATION
FIGURES
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
TABLES
TABLE 1.1 DIGITAL OUTPUTS
TABLE 1.2 CONTROL INPUTS
1.1Preface
1.0INTRODUCTION
COVERAGE
1.2 WARRANTY POLICY
ADVANCED POLLUTION INSTRUMENTATION DIVISION
02024c
1.3 Principle of Operation
Page
1.5 Installation 19” Rack Mount Enclosure
1.4 Specifications
Page
5.If the M450H has been configured with the auto-zerovalve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line
1.6 Installation NEMA 4X Wall Mount Enclosure
ozone
FIGURE 1.1 - NEMA 4X MOUNTING HOLE DIMENSIONS
FIGURE 1.2 - NEMA 4X ELECTRICAL POWER CONNECTIONS
FIGURE 1.3 - NEMA 4X PNEUMATIC CONNECTIONS
1.6.2 Relay Outputs
FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS
1.6Electrical I/O Connections
1.6.1Analog Output
Description
FIGURE 1.5 - CONNECTING DIGITAL OUTPUTS
1.6.4 Control Inputs
Output
Zero Calibrate
1.6.5 RS232 Output
Input
CONTROL INPUTS
D C P O W E R SO
FIGURE 1.6 - NEMA4X ASSEMBLY LAYOUT
FIGURE 1.7 - M450H PNEUMATIC BLOCK DIAGRAM
U V L A M P M O T H E R B V / F C P U A C L I N E
POWER SUPPLY MODULE
Figure 1.8 - 19” Rack Assembly Layout
1.7 Operation verification
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
1.8.2 Isolated Current Output 4-20mAor 2-20mA
1.8.5 Flow Switch
1.8 Options
1.8.1 Auto-ZeroOption
2.0OPERATION
2.1Key features
2.1.2 Concentration Alarms
2.1.4 E2 ROM backup of software configuration
Mode Field
2.2 Front Panel Display
2.2.1 Front panel display fields
FIGURE 2.1 - MODEL 450H FRONT PANEL
Warning Message
Message/Test Measurement Field
Test Message
TEST MEASUREMENTS
State
2.3 Software Operation
2.2.2 Status LED’s
2.3.1 Main Menu
Audible Beeper
2.3.3 Alarm Status Menu
FIGURE 2.3 - ALARM STATUS MENU
Clearing Alarms
Page
FIGURE 3.1 - SETUP MENU
3.0 SETUP MODE
HI ALARM OFF
3.1 Setting the Concentration Alarms ALRM
3.2 Setting the Concentration Units UNIT
3.3 Setting the time-of-dayand date CLK
3.4 Setting the RS-232baud rate COMM
3 AZERO ENABLE
3.5 Setup variables VARS
0 LATCH_ALARMS
1 ALARM BEEPER
9 CONCENTRATION RANGE
8 GAS MOLECULAR WEIGHT
10 TPC ENABLE
7 AZERO HOLD OFF
3.5.3 Analog Output
3.5Diagnostics DIAG
3.5.1Zero Calibration
3.5.2 D/A Calibration
Filter Replacement Procedure
4.0Maintenance
4.2Cleaning Exterior Surfaces of the M450H
4.3 Cleaning the Optical Cell
4.4 Degree of Protection
FIGURE 4.1 MEASUREMENT CELL DISASSEMBLY
5.2Changing the analog output range
5.0 ADJUSTMENTS
Switch Settings
5.1 Calibration
1.Press SETUP-DIAG
5.3 A/D - D/A Calibration Procedure
FIGURE 4.2- ANALOG OUTPUT JUMPERS
5.4 Current Loop Calibration
zero point can be adjusted anywhere between 0 and 4 milliamps. Press ENTR when you have reached the desired zero point as measured by your test meter
APPENDIX A - SOFTWARE MENU TREE
Page
DESCRIPTION
APPENDIX B - SPARE PARTS LIST
Page
Drawing Number
APPENDIX C - ELECTRICAL SCHEMATIC INDEX
Title
Related pages
Troubleshooting for Coleman 9992-647
Technical Specifications for Hypertec TARS0501HY
Indicator lights for Electrolux ESF2450
Flowchart 2.14-No OS Loading, Optical Drive for FHP DV1400
HOW TO STOP YOUR UNIT for Poulan 530088147
Check Local Codes Prior to Installation for Desa EVDDVF36PN
Parts List for Soleus Air SG-WAC-15ESE
Pre-programming Code List for Onkyo DV-SP501
Personal settings for Philips UCZZ01930AB
Section VI Specifications for Johnson Controls 22 SEER
What models are similar to UE32J4000AWXXC regarding time settings?
See similar models
Top
Page
Image
Contents