MODEL 450H OZONE MONITOR
EMAIL api-sales@teledyne.com
SAFETY MESSAGES
4.0 MAINTENANCE
TABLE OF CONTENTS
3.0 SETUP MODE
5.0 ADJUSTMENTS
5.4 CURRENT LOOP CALIBRATION
APPENDIX A - ELECTRICAL SCHEMATIC INDEX
5.3 A/D - D/A CALIBRATION PROCEDURE…
FIGURES
TABLE 1.2 CONTROL INPUTS
TABLES
TABLE 1.1 DIGITAL OUTPUTS
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
1.0INTRODUCTION
1.1Preface
02024c
1.2 WARRANTY POLICY
ADVANCED POLLUTION INSTRUMENTATION DIVISION
COVERAGE
1.3 Principle of Operation
Page
1.4 Specifications
1.5 Installation 19” Rack Mount Enclosure
Page
5.If the M450H has been configured with the auto-zerovalve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line
1.6 Installation NEMA 4X Wall Mount Enclosure
ozone
FIGURE 1.1 - NEMA 4X MOUNTING HOLE DIMENSIONS
FIGURE 1.2 - NEMA 4X ELECTRICAL POWER CONNECTIONS
FIGURE 1.3 - NEMA 4X PNEUMATIC CONNECTIONS
1.6.1Analog Output
FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS
1.6Electrical I/O Connections
1.6.2 Relay Outputs
Output
FIGURE 1.5 - CONNECTING DIGITAL OUTPUTS
1.6.4 Control Inputs
Description
CONTROL INPUTS
1.6.5 RS232 Output
Input
Zero Calibrate
U V L A M P M O T H E R B V / F C P U A C L I N E
FIGURE 1.6 - NEMA4X ASSEMBLY LAYOUT
FIGURE 1.7 - M450H PNEUMATIC BLOCK DIAGRAM
D C P O W E R SO
Figure 1.8 - 19” Rack Assembly Layout
POWER SUPPLY MODULE
1.7 Operation verification
TABLE 1.3 FINAL TEST AND CALIBRATION VALUES
1.8.1 Auto-ZeroOption
1.8.5 Flow Switch
1.8 Options
1.8.2 Isolated Current Output 4-20mAor 2-20mA
2.1.4 E2 ROM backup of software configuration
2.1Key features
2.1.2 Concentration Alarms
2.0OPERATION
FIGURE 2.1 - MODEL 450H FRONT PANEL
2.2 Front Panel Display
2.2.1 Front panel display fields
Mode Field
TEST MEASUREMENTS
Message/Test Measurement Field
Test Message
Warning Message
2.3.1 Main Menu
2.3 Software Operation
2.2.2 Status LED’s
State
Clearing Alarms
2.3.3 Alarm Status Menu
FIGURE 2.3 - ALARM STATUS MENU
Audible Beeper
Page
3.0 SETUP MODE
FIGURE 3.1 - SETUP MENU
3.3 Setting the time-of-dayand date CLK
3.1 Setting the Concentration Alarms ALRM
3.2 Setting the Concentration Units UNIT
HI ALARM OFF
3.4 Setting the RS-232baud rate COMM
1 ALARM BEEPER
3.5 Setup variables VARS
0 LATCH_ALARMS
3 AZERO ENABLE
7 AZERO HOLD OFF
8 GAS MOLECULAR WEIGHT
10 TPC ENABLE
9 CONCENTRATION RANGE
3.5.2 D/A Calibration
3.5Diagnostics DIAG
3.5.1Zero Calibration
3.5.3 Analog Output
4.3 Cleaning the Optical Cell
4.0Maintenance
4.2Cleaning Exterior Surfaces of the M450H
Filter Replacement Procedure
FIGURE 4.1 MEASUREMENT CELL DISASSEMBLY
4.4 Degree of Protection
5.1 Calibration
5.0 ADJUSTMENTS
Switch Settings
5.2Changing the analog output range
FIGURE 4.2- ANALOG OUTPUT JUMPERS
5.3 A/D - D/A Calibration Procedure
1.Press SETUP-DIAG
5.4 Current Loop Calibration
zero point can be adjusted anywhere between 0 and 4 milliamps. Press ENTR when you have reached the desired zero point as measured by your test meter
APPENDIX A - SOFTWARE MENU TREE
Page
APPENDIX B - SPARE PARTS LIST
DESCRIPTION
Page
Title
APPENDIX C - ELECTRICAL SCHEMATIC INDEX
Drawing Number
Related pages
All Diagnostic page
Diagnostics for Xerox MAX 200
Diagnostic Information Sources for Sun Microsystems 5310 NAS
Diagnostics for Dell T5600
−17. Diagnostic Register Description for Texas Instruments PCI7611
Downloading HP PC Hardware Diagnostics to a USB device for HP 200 G1
Diagnostic Information for Lexmark 4076-0XX
LAN Test Tests and Diagnostics for Toshiba A10
Certification Checklist Diagnostic Procedures for Braun 32221
Diagnostics for Cisco Systems 7935
Starte Dell Diagnostics fra harddisken for Dell Workstation 370
Where can I locate the
full Aroma rice cooker manual
?
Top
Page
Image
Contents