3.0 SETUP MODE

3.0 SETUP MODE

This section describes the setup variables which are used to configure the Monitor. All the setup variables are stored in the Monitor's EEPROM and are retained during power off and even when new software revisions are installed.

NOTE

If a variable is modified, but ENTR is not pressed, the variable will not be changed and the monitor will beep when exit is pressed.

The setup menus are accessed by pressing the SETUP button from the instrument’s main menu. The top level setup menu is shown in Figure 3.1 below.

SETUP A.8

ALRM

 

UNIT

 

CLK COMM VARS DIAG

 

EXIT

FIGURE 3.1 - SETUP MENU

P/N 02826B1 Teledyne API Model 450H O3 Monitor Instruction Manual - Page 33

Image 33
Contents MODEL 450H OZONE MONITOR EMAIL api-sales@teledyne.comPrinted 05/15/06 SAFETY MESSAGES 3.0 SETUP MODE TABLE OF CONTENTS4.0 MAINTENANCE 5.0 ADJUSTMENTSAPPENDIX A - ELECTRICAL SCHEMATIC INDEX 5.3 A/D - D/A CALIBRATION PROCEDURE…5.4 CURRENT LOOP CALIBRATION FIGURES TABLE 1.1 DIGITAL OUTPUTS TABLESTABLE 1.2 CONTROL INPUTS TABLE 1.3 FINAL TEST AND CALIBRATION VALUES1.1Preface 1.0INTRODUCTIONADVANCED POLLUTION INSTRUMENTATION DIVISION 1.2 WARRANTY POLICY02024c COVERAGE1.3 Principle of Operation Page 1.5 Installation 19” Rack Mount Enclosure 1.4 SpecificationsPage 5.If the M450H has been configured with the auto-zerovalve option, connect the oxygen or other zero gas source to the ¼” tube fitting labeled ‘Zero Gas Inlet.’ Do not exceed 30 psig in the zero air delivery line 1.6 Installation NEMA 4X Wall Mount Enclosure ozone FIGURE 1.1 - NEMA 4X MOUNTING HOLE DIMENSIONS FIGURE 1.2 - NEMA 4X ELECTRICAL POWER CONNECTIONS FIGURE 1.3 - NEMA 4X PNEUMATIC CONNECTIONS 1.6Electrical I/O Connections FIGURE 1.4 - ELECTRICAL SIGNAL I/O CONNECTIONS1.6.1Analog Output 1.6.2 Relay Outputs1.6.4 Control Inputs FIGURE 1.5 - CONNECTING DIGITAL OUTPUTSOutput DescriptionInput 1.6.5 RS232 OutputCONTROL INPUTS Zero CalibrateFIGURE 1.7 - M450H PNEUMATIC BLOCK DIAGRAM FIGURE 1.6 - NEMA4X ASSEMBLY LAYOUTU V L A M P M O T H E R B V / F C P U A C L I N E D C P O W E R SOPOWER SUPPLY MODULE Figure 1.8 - 19” Rack Assembly Layout1.7 Operation verification TABLE 1.3 FINAL TEST AND CALIBRATION VALUES 1.8 Options 1.8.5 Flow Switch1.8.1 Auto-ZeroOption 1.8.2 Isolated Current Output 4-20mAor 2-20mA2.1.2 Concentration Alarms 2.1Key features2.1.4 E2 ROM backup of software configuration 2.0OPERATION2.2.1 Front panel display fields 2.2 Front Panel DisplayFIGURE 2.1 - MODEL 450H FRONT PANEL Mode FieldTest Message Message/Test Measurement FieldTEST MEASUREMENTS Warning Message2.2.2 Status LED’s 2.3 Software Operation2.3.1 Main Menu StateFIGURE 2.3 - ALARM STATUS MENU 2.3.3 Alarm Status MenuClearing Alarms Audible BeeperPage FIGURE 3.1 - SETUP MENU 3.0 SETUP MODE3.2 Setting the Concentration Units UNIT 3.1 Setting the Concentration Alarms ALRM3.3 Setting the time-of-dayand date CLK HI ALARM OFF3.4 Setting the RS-232baud rate COMM 0 LATCH_ALARMS 3.5 Setup variables VARS1 ALARM BEEPER 3 AZERO ENABLE10 TPC ENABLE 8 GAS MOLECULAR WEIGHT7 AZERO HOLD OFF 9 CONCENTRATION RANGE3.5.1Zero Calibration 3.5Diagnostics DIAG3.5.2 D/A Calibration 3.5.3 Analog Output4.2Cleaning Exterior Surfaces of the M450H 4.0Maintenance4.3 Cleaning the Optical Cell Filter Replacement Procedure4.4 Degree of Protection FIGURE 4.1 MEASUREMENT CELL DISASSEMBLYSwitch Settings 5.0 ADJUSTMENTS5.1 Calibration 5.2Changing the analog output range5.3 A/D - D/A Calibration Procedure 1.Press SETUP-DIAGFIGURE 4.2- ANALOG OUTPUT JUMPERS 5.4 Current Loop Calibration zero point can be adjusted anywhere between 0 and 4 milliamps. Press ENTR when you have reached the desired zero point as measured by your test meter APPENDIX A - SOFTWARE MENU TREE Page DESCRIPTION APPENDIX B - SPARE PARTS LISTPage APPENDIX C - ELECTRICAL SCHEMATIC INDEX Drawing NumberTitle