Cornelius 1550 installation manual Operating Clearances, Adjustments, Cooling Unit Maintenance

Page 17

BEER FAUCET (2)

UNIT POWER SWITCH

DRIP TRAY/CUP REST

(115 VAC, 60 HZ UNIT ONLY)

FIGURE 3. 1550 UNIVERSAL BEER DISPENSER

OPERATING CLEARANCES

Check area in front, back, sides, and above the Unit for obstructions. These areas must be kept clear at all times. Listed below are the minimum clearances that must be maintained.

A.Clearance above the Unit –––––––––––––––––––––––––––––12 inches to nearest obstruction.

B.Clearance back of Unit –––––––––––––––––––––––––––––––12 inches to nearest obstruction.

C.Clearance on sides of Unit –––––––––––––––––––––––––––––12 inches to nearest obstruction.

D.Clearance on front of Unit –––––––––––––––––––––––––––––Open

ADJUSTMENTS

ADJUSTING CO2 REGULATORS

(see Figure 2)

The CO2 regulators should be periodically checked for proper pressure settings and if necessary, be adjusted by a qualified Service Person.

ADJUSTING DISPENSED BEER FLOW RATE

Dispensed beer flow rate of the dispensing faucets should be periodically checked and if necessary, be adjusted by a qualified Service Person.

COOLING UNIT MAINTENANCE

CLEANING CONDENSER COIL

NOTE: Air circulation through the condenser coil, required to cool the coil, is drawn in through grille on Unit front panel and is exhausted out through grilles on sides and back of the Unit. Restricting air flow through the condenser coil will decrease cooling efficiency of the Unit.

Area in front, sides, and back of the Unit must be kept free of obstructions at all times which would prevent air flow in and out of the Unit.

569000246

12

Image 17
Contents This Document Contains Important Information Installation ManualTable of Contents Table of Contents cont’d Recognize Safety Information Safety InformationPage This page Left Blank Intentionally General Information Warranty Reference InformationGeneral Description Design DataUniversal Beer Dispenser Theory of OperationFlow Diagram Page This page Left Blank Intentionally Selecting Location InstallationUnpacking and Inspection Fill Water Tank and Start Refrigeration System InstallationPreparing Unit for Operation Connecting CO2 System to Beer KEG TappersConnecting Beer Source Supplies to Unit Unit Operation Proper Beer Storage OPERATOR’S InstructionsOperating Controls Daily PRE-OPERATION CheckOperating Clearances AdjustmentsCooling Unit Maintenance Cleaning CO2 System GAS Check Valves Cleaning and SanitizingReplenishing CO2 Supply Replenishing Beer SupplyPage This page Left Blank Intentionally Adjusting CO2 Regulators Service and MaintenancePreparing Unit for SHIPPING, RELOCATING, or Storing Periodic InspectionDispenser Components Parts Identification Beer Faucet Adjustment Unit Maintenance Cleaning Condenser CoilChecking ICE Water Bath Cleaning Water TankSanitize Beer Systems Replenishing CO2 Supply CO2 GAS Check Valve Cleaning CO2 GAS Check Valve Wiring Diagram Troubleshooting Rate TOO High Temperature TOO WarmOFF-TASTE Beer Sour UnpalatableCompressor does not Coolant Sufficiently Installation SectionOperate Compressor will notOperating RefrigerationCompressor not Warranty One Cornelius Place Anoka, Minnesota 612 800