Cornelius 1550 installation manual Replenishing CO2 Supply

Page 27

5.Connect tank containing detergent solution into the beer system.

6.Place waste container under applicable beer faucet.

7.Activate the beer faucet to permit detergent solution to purge beer out of the line, coil, and the beer faucet. Continue to dispense until all beer has been purged from the beer system and only detergent solution is dispensed from the beer faucet.

8.Disconnect tank containing detergent solution from the beer system.

9.Using a clean syrup tank, prepare sanitizing solution using 70° F (21° C) to 100° F (38° C) potable water and 0.5 oz. (15 ml) of household liquid bleach such as non-scented Hi-Lex or Chlorox that contains a 5.25 % sodium hypochlorite concentration to one gallon of potable water. This mixture must not exceed 200 PPM of chlorine. Shake tank containing sanitizing solution to thoroughly mix the solution.

10.Connect tank containing sanitizing solution into the beer system.

11.Place waste container under the applicable beer faucet.

12.Activate the beer faucet to permit sanitizing solution to purge detergent solution out of the line, coil, and the beer faucet. Continue to dispense until all detergent solution has been purged from the beer system and until only sanitizing solution is dispensed.

13.Allow sanitizing solution to remain in the beer system for not less than 10-minutes or for more than 15-min- utes.

14.Disconnect tank containing sanitizing solution from the beer system.

WARNING: Flush all sanitizing solution from the beer system as instructed. Residual sanitizing solution left in the beer system could create a health hazard.

15.Connect tank containing potable water into the beer system.

16.Place waste container under the applicable beer faucet.

17.Activate the beer faucet to permit potable water to purge sanitizing solution out of the beer system. Contin- ue to dispense until all sanitizing has been purged from the beer system and only potable water is dispensed.

18.Disconnect tank containing potable water from the beer system.

19.Place the beer keg tapper in a pail container containing sanitizing. Completely wash the beer keg tapper in the sanitizing solution, then thoroughly rinse the tapper with potable water.

20.Install beer keg tapper in beer keg.

21.Open CO2 shutoff valve in beer keg tapper CO2 line, then open beer shutoff valve in beer keg tapper beer line.

22.Place waste container under applicable beer faucet. Dispense from beer faucet until all potable water has been purged from the beer system and only beer is dispensed.

23.Repeat preceding steps 1 through 22 to sanitize the other beer system.

REPLENISHING CO2 SUPPLY

NOTE: When indicator on CO2 cylinder regulator assembly 1800 psi gage is in shaded (‘‘change CO2 cylinder’’) portion of dial, CO2 cylinder is almost empty and should be replaced.

CAUTION: Wear protective eyewear to avoid injury from gas-driven particles.

21

569000246

Image 27
Contents This Document Contains Important Information Installation ManualTable of Contents Table of Contents cont’d Recognize Safety Information Safety InformationPage This page Left Blank Intentionally Design Data Warranty Reference InformationGeneral Information General DescriptionUniversal Beer Dispenser Theory of OperationFlow Diagram Page This page Left Blank Intentionally Installation Unpacking and InspectionSelecting Location Fill Water Tank and Start Refrigeration System InstallationConnecting CO2 System to Beer KEG Tappers Connecting Beer Source Supplies to UnitPreparing Unit for Operation Unit Operation Daily PRE-OPERATION Check OPERATOR’S InstructionsProper Beer Storage Operating ControlsAdjustments Cooling Unit MaintenanceOperating Clearances Replenishing Beer Supply Cleaning and SanitizingCleaning CO2 System GAS Check Valves Replenishing CO2 SupplyPage This page Left Blank Intentionally Periodic Inspection Service and MaintenanceAdjusting CO2 Regulators Preparing Unit for SHIPPING, RELOCATING, or StoringDispenser Components Parts Identification Beer Faucet Adjustment Unit Maintenance Cleaning Condenser CoilChecking ICE Water Bath Cleaning Water TankSanitize Beer Systems Replenishing CO2 Supply CO2 GAS Check Valve Cleaning CO2 GAS Check Valve Wiring Diagram Troubleshooting Unpalatable Temperature TOO WarmRate TOO High OFF-TASTE Beer SourCompressor will not Coolant Sufficiently Installation SectionCompressor does not OperateRefrigeration Compressor notOperating Warranty One Cornelius Place Anoka, Minnesota 612 800