30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
4. Electrical Connection to the Range |
(U.S.A.) |
Three Conductor Wire Connection to Range
If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 3):
1.Remove the 3 screws at the lower end of the rear wire cover, then bend the lower end of the rear wire cover (access cover) upward to expose range terminal connection block (see Figure 2).
2.Using the nuts supplied in the literature package, connect the neutral of the copper power supply cord to the center
3.Lower the terminal cover and replace the 3 screws.
Silver Colored Terminal
Red Wire
Terminal | Cord | |
Block | ||
Mounting | ||
| ||
| Plate | |
Black | Neutral | |
Wire | (White Wire) | |
| Grounding | |
| Strap |
A User Supplied |
| 1 1/8" (2.9 cm) Dia. | |
| Direct Connection | ||
| |||
To 240 V | Hole. Punch Out | ||
Be Installed at This | |||
Knockout for 1 3/8" | |||
Location. | Receptacle | ||
(3.5 cm) Dia. Cord | |||
|
| ||
| Figure 3 | Kit Hole. | |
|
|
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 4):
1.Remove the 3 screws at the lower end of the rear wire cover, then raise the lower end of the rear wire cover (access cover) upward to expose range terminal connection block (see figure 2).
2.Remove the grounding strap from the terminal block and from the appliance frame.
3.Using the nuts supplied with the literature package, connect the ground wire (green) of the copper power supply cord to the frame of the appliance with the ground screw, using the hole in the frame where the ground strap was removed (see Figure 4).
4.Connect the neutral of the copper power supply cord to the center
5.Lower the terminal cover and replace the 3 screws.
Terminal Block | Silver Colored Terminal |
Red
Wire
Black Wire |
|
1 1/8" (2.9cm) |
|
Dia. Direct |
|
Connection |
|
Hole. Punch | Neutral |
Out Knockout | (White Wire) |
for 1 3/8" | Ground (Bare |
(3.5cm) Dia. | |
Cord Kit Hole. | Copper Wire) |
A User Supplied |
|
| |
Be Installed at This |
|
Location | To 240 V Receptacle |
NOTE: Be sure to remove the supplied grounding strap.
Figure 4
6