Installation Instructions
G
Bake and Broil Burners
G1 CheckingBurners the Oven The
G2 To Adjust the Air Shutter
To check the bake burner flames with the oven door in the closed position:
1. | Open the door. |
2. | Remove the oven bottom. |
a. Slide the tab to the left to unlock. |
BAKE BURNER
1.Remove the orifice fitting cover.
2.Use a screwdriver to loosen the air shutter screw.
Orifice Fitting
Cover
Air Shutter | Air Shutter |
Screw |
|
b. Lift the oven bottom up and out. |
UnlockLock
3.Remove the two screws holding the burner baffle (flame spreader) to the burner box.
2Screws
4.Close the oven door.
5.Turn on the bake or broil burner.
As you watch the flames, check the following:
•Burner flames should not flutter or blow away from the burner.
•They should be blue in color with no trace of yellow.
3.Adjust the air shutter.
4.Retighten the air shutter screw.
WHAT ADJUSTMENT TO MAKE:
a.If the flames are yellow, open the air shutter more than the original setting.
b.If the flames blow away or fluttered from the burner, close the air shutter more than the original setting.
Burners should be checked frequently.
BROIL BURNER
1.The broil burner is located and accessible in the top rear of the oven.
2. Using a
screwdriver, |
|
loosen the air | Air |
shutter | Shutter |
Air Shutter | |
adjustment | Screw |
| |
screw. |
|
3.Make the air shutter adjustment.
4.Retighten the air shutter screw.
5. Check the inner cone of | Inner Cone of Flame | |
1/2" To 3/4" | ||
the flame. It should be | ||
Burner | ||
| Oven Broiler | |
between 1/2" and 3/4" |
| |
long for the oven bake |
| |
and broil burners. |
|
WHEN ALL ADJUSTMENTS ARE MADE AND THE RESULTS ARE SATISFACTORY
1.Replace the orifice fitting cover.
2.Replace the burner baffle (flame spreader) and screws.
3.Replace the oven bottom.
11