Southbend SSB-36, SSB-45, SSB-32 owner manual Connect Gas Supply, Check The Installation, PAGE 14 OF

Page 14
STEP 3: CONNECT GAS SUPPLY

INSTALLATION

RADIANT STEAKHOUSE BROILER

STEP 3: CONNECT GAS SUPPLY

If the broiler is being installed at over 2,000 feet (610 meters) altitude and that information was not specified when ordered, contact the appropriate authorized Southbend Service Representative or the Southbend Service Department. Failure to install with proper orifice sizing will result in poor performance and may void the warranty.

The broiler is design-certified for operation on natural or propane gases. The broiler is shipped configured and adjusted for the type of gas specified by the purchaser, which is indicated on the serial plate (see Figure 1 on page 3). Connect the broiler ONLY to the type of gas for which it is configured and adjusted.

The broiler will have a 1" NPT female thread in the regulator at the rear of the unit, or may be connected by the front manifold when connected to a battery of other sectional equipment.

Minimum supply pressure is 7" W.C. for natural gas, 11" W.C. for propane. An external pressure regulator is provided. If using a flexible-hose gas connection, the inside diameter of the hose must not be smaller than the connector on the broiler, and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent undue strain on the gas connection.

If applicable, a vent line from the gas appliance pressure regulator must be installed to the outdoors in accordance with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1,or the Propane Installation Code CAN/CGA-B149.2,as applicable.

An adequate gas supply is imperative. Undersized or low-pressure lines will restrict the volume of gas required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect burner-operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold pressure. The supply line to the broiler should be no smaller than the inside diameter of the pipe on the broiler to which it is connected.

STEP 4: CHECK THE INSTALLATION CAUTION

ALL PIPE JOINTS AND CONNECTIONS MUST BE TESTED THOROUGHLY FOR GAS LEAKS. USE ONLY SOAPY WATER FOR TESTING ON ALL GASES. NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. ALL CONNECTIONS MUST BE CHECKED FOR LEAKS AFTER THE APPLIANCE HAS BEEN PUT INTO OPERATION. TEST PRESSURE SHOULD NOT EXCEED 14" W.C.

1.Check that the control valves on the broiler are in the OFF position.

2.Purge the gas supply line to clean out dust, dirt, or other foreign matter before connecting the line to the broiler.

3.For stand mount and countertop mounting, connect the gas supply to the inlet at right rear corner.

PAGE 14 OF 20 CAUTION

HOLD THE INLET SUPPLY PIPE WITH A WRENCH WHEN TIGHTENING ADDED FITTINGS TO AVOID DAMAGE TO THE REGULATOR, VALVE, AND OTHER COMPONENTS.

4. Turn on the gas and check for leaks using soapy water.

STEP 4: CHECK THE INSTALLATION

1.Check that all screws and bolts are tightened.

2.Check that the gas connection has been made correctly.

3.Move the broiler into the final position at which it will be operated.

4.Check that the broiler is level.

5.Check that the appropriate minimum clearances are satisfied (see page 4), including adequate clearance for combustion air to enter the rear of the broiler.

6.Check that there is sufficient clearance to pull out the broiler rack, grease drawer, and griddle grease chute; and to operate the rack-height adjustment lever.

7.Check that adequate ventilation (fresh air supply and hood exhaust) is available to the room in which the appliance will operate.

8.Wipe clean all surfaces.

PAGE 14 OF 20

OWNERS MANUAL 1190950 (02/09)

Image 14
Contents Models SSB-32, SSB-36, and SSB-45 Platinum Series Radiant Steakhouse BroilerBURN HAZARD FIRE HAZARD FOR YOUR SAFETYDANGER EXPLOSION AND ASPHYXIATION HAZARDINTRODUCTION Location of Serial PlateCLEARANCES SPECIFICATIONSMINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION Total BTU’s DIMENSIONSVENTILATION BurnersBurner Orifice GAS SUPPLYGas Type Bar PilotOPERATION OF RADIANT STEAKHOUSE BROILER OPERATIONDANGER EXPLOSION HAZARD LIGHTING BROILER PILOTS Broiler Controls and ComponentsLIGHTING AFTER GAS HAS BEEN SHUT OFF SHUTDOWN OF BROILERMONTHLY CLEANING AND MAINTENANCE CLEANING & MAINTENANCEDAILY CLEANING AND MAINTENANCE SEMIANNUAL CLEANING AND MAINTENANCEPAGE 10 OF CARE OF GRIDDLESSTAINLESS-STEEL SURFACES STEP 1 UNPACKING INSTALLATIONIMMEDIATELY INSPECT FOR SHIPPING DAMAGE Mounting Broiler on Stand STEP 2A MOUNT ON HEAVY DUTY STANDInstallation on Countertop STEP 2B ATTACH COUNTERTOP LEGSPAGE 14 OF STEP 4 CHECK THE INSTALLATIONSTEP 3 CONNECT GAS SUPPLY STEP 6 WIPE-CLEAN AND SHUT-DOWN APPLIANCE STEP 5 CHECK BROILER OPERATIONProblem SERVICETROUBLESHOOTING Look forADJUSTMENT OF BROILER PILOTS Access to Serviceable PartsACCESS TO SERVICEABLE PARTS PARTS ADJUSTMENT OF BROILER BURNERSADJUSTMENT OF GAS PRESSURE REGULATOR PAGE 19 OF PLATINUM SERIES RADIANT STEAKHOUSE BROILER Stand Mount, Countertop, Cabinet Base or Refrigeration Base