PB Heat 211A manual Base Front Panel Cover Plate 26 660 mm Wide Base Panel

Page 55

REPAIR PARTS – SERIES 211A

Item

No.

Description

Part Selection Information

Stock

Code

 

 

14-3/4" (375 mm) Wide Base Panel

90316

 

 

 

 

 

 

20-3/8" (518 mm) Wide Base Panel

90318

 

 

 

 

17

Base Front Panel Cover Plate

26" (660 mm) Wide Base Panel

90320

 

 

 

 

 

 

31-5/8" (803 mm) Wide Base Panel

90322

 

 

 

 

 

 

37-1/4" (946 mm) Wide Base Panel

90324

 

 

 

 

 

 

14-3/4" (375 mm) Wide Base Panel

90317

 

 

 

 

 

 

20-3/8" (518 mm) Wide Base Panel

90319

 

 

 

 

18

Base Back Panel Cover Plate

26" (660 mm) Wide Base Panel

90321

 

 

 

 

 

 

31-5/8" (803 mm) Wide Base Panel

90323

 

 

 

 

 

 

37-1/4" (946 mm) Wide Base Panel

90325

 

 

 

 

19

Manifold Weldment

Specify Control System

 

 

 

 

 

20

Orifice Spud

Specify Quantity Type of Gas and Altitude

 

 

 

 

 

21

Steel Burner

Specify Quantity Required

51045

 

 

 

 

 

Steel Burner w/Pilot Mounting Clip

Specify w/ or w/o Pilot and Pilot Number

51046

 

 

 

 

 

 

16" (406 mm) Wide

90557

 

 

 

 

22

Flue Collector

21-9/16" (548 mm) Wide

90558

 

 

 

 

 

 

27-1/8" (689 mm) Wide

90559

 

 

 

 

 

 

For GG-5000 w/ 12" (305 mm) Dia. Outlet

90399

 

 

 

 

23

Draft Hood

For GG-5000-1 w/ 12" (305 mm) Dia. Outlet

90400

 

 

For GG-5000-1 w/ 14" (356 mm) Dia. Outlet

90401

 

 

 

 

 

 

 

 

For GG-5000-2 w/ 14" (356 mm) Dia. Outlet

90402

 

 

 

 

24

Front Flue Collector Hook Bolt

1 Required Per Flue Collector

GG5003

 

 

 

 

25

Black Flue Collector Hook Bolt

1 Required Per Flue Collector

GG5004

 

 

 

 

26

Flue Collector Mounting Bracket

1 Required Per Flue Collector

 

 

 

 

 

27

Hi Temp Rope for Flue Collector, 5/8" (16 mm)

Specify Quantity in Feet (Meters) Required

55723

 

 

 

 

28

Cleanout Cover Plate Sub-Assembly

Set of 2

90489

 

 

 

 

29

Hi Temp Rope for Cleanout Cover Plate, 5/8" (16 mm)

Specify Quantity in Feet (Meters) Required

55723

 

 

 

 

 

Common End Panel and Cleanout Cover Plate

Carton No. 12

90282

 

Assembly

 

 

 

 

 

 

 

 

Carton No. 12A

90283

 

 

 

 

 

 

Carton No. 12B

90284

 

 

 

 

 

Intermediate Panel Jacket Assembly

Carton No. 12C

90285

 

 

 

 

 

 

Carton No. 12D

90286

 

 

 

 

 

 

Carton No. 12E

90287

 

 

 

 

 

Pilot Line Assembly

Specify Control System

 

 

 

 

 

 

Pilot Line Support Bracket

Specify Quantity Required

 

 

 

 

 

 

Gas Control Assembly

Specify Control System

 

 

 

 

 

 

Steam Gauge

Steam Boilers Only

51769

 

 

 

 

 

Gauge Glass Set

Steam Boilers Only

50513

 

 

 

 

 

Lighting Instruction Plate

Specify Control System

 

 

 

 

 

 

Hi Temp Sealing Cement

Specify Quantity of Containers

55726

 

 

 

 

 

Spray Adhesive

Specify Quantity of Containers

55485

 

 

 

 

 

¹⁄₄" O.D. Aluminum Tubing

Specify Quantity in Feet (Meters)

718

 

 

 

 

 

³⁄₈" O.D. Aluminum Tubing

Specify Quantity in Feet (Meters)

719

 

 

 

 

53

Image 55
Contents Series 211A Table of Contents Special Attention Boxes Using this ManualFollow the Piping Guidelines ControlsAIR for Combustion and Ventilation PreinstallationAccessibility Clearances Combustible Construction ClearancesRequired Volume fan = 15 ft Required Volume other =21 ft Input for all appliances in the space. See Btu/hr 22 cm 2 per 2000 W of total ratedCombustion Air Ducts Chimney or VentWhere Mechanical Combustion Air SupplyVent Sizing Exterior VentsCombined vent breeching Installation Survey Boiler SettingWater Quality and MAKE-UP Boiler Foundation Layout Assemble the Base Base AssemblyCrate Items For 211A-04 through 211A-08 Only Install the Pilot BurnersModel Overall Length Base Front and Back Panel CratesTypical Gas Manifold and Pilot Line Assembly Pilots Total Natural Gas Only Propane Gas Only Model NumberBurners Preparation Place the Boiler SectionsPlacing the Sections Assembling Sections on Base Align Sections Vertically Hydrostatic Test the BoilerDo not tighten yet Install the Flue CollectorBoiler Position Supply Piping Pipe the BoilerReturn Piping Pipe the Boiler Model Size Multiple Boiler InstallationsBoiler Header End Risers EqualizersPiping Multiple Boilers, Typical, Gravity Return Systems Apply Jacket END Assemblies Install the Jacket & Draft HoodApply Cleanout Cover Plates Prepare the PartsApply Jacket TOP Panels Apply Lower END PanelsApply Plates and Labels Top Panel GG-6024 Carton Contents Sub-Assembly Part Number Quantity Jacket Assembly Sequence Carton Numbers and Locations 13C Connect Pilot GAS Tubing Install GAS TrainInstall Vent and Bleed Piping Connect GAS PipingTest GAS Supply Piping Install GAS Supply PipingSpecific Gravity Multiply Capacity by Pipe Length 4 Pipe 2 PipeInstall Pressure Controls Install Controls and TrimInstall Safety Valves Install LOW Water CUT-OFFS Install Blowdown ValvesPressure Control Piping Fittings Included with Boiler Standard Float Type COntrol, Model 67PE2 Optional Float Type Pump Control/Low Water Cut-Off, Model Application of 51 Feeders Prepare Remaining Controls Wire the BoilerConnect Supply Wiring Install Control WiringTypical Wiring Standard Controls Low Voltage Gas Valves Typical Wiring Standard Controls 120-Volt Gas Valves Starting the Boiler Check Boiler Controls Clean the BoilerMeter reading. Rate, Btu/Hr = F x H x To Light the Boiler To Shut Down the Boiler Lighting Instructions TypicalPilot Flame Failure Operation & Maintenance Pilot and Burner Flames Placing Boiler in OperationDaily Maintenance Monthly MaintenanceAnnual Maintenance Weekly MaintenanceProblem Possible Cause Suggested Remedy Troubleshooting Service TipsCorrect Piping Boiler Rating Information Boiler Ratings & DimensionsBoiler Ratings & Dimensions Series 211A Steam Boiler Dimensions Chart continues onSeries 211A Steam Boiler Dimensions Description Part Selection Information Stock Code Repair Parts Series 211ABase Front Panel Cover Plate 26 660 mm Wide Base Panel Boiler Assembly Base Assembly Page Series 211A