PREVENTIVE
MAINTENANCE
Preventive maintenance should be done in daily, weekly, monthly and yearly intervals as necessary. Following preventive maintenance procedures will help keep your Pasta System working efficiently. Proper care and servicing will lead to years of quality performance.
NOTE: The most important part of any maintenance program is daily cleaning. Ninety percent of any maintenance problem is directly or indirectly related to cleanliness.
NOTE: Water level problems caused by the sensors not being cleaned adequately will not be covered under warranty.
PREVENTIVE MAINTENANCE CHART
TIME FRAME | OPERATOR/OWNER | SECTION |
Hourly | • Clean sensor tube with a brush |
|
|
|
|
Daily | • Check lights and controls. | III |
| • Check water level. |
|
| • Clean all baskets. |
|
|
|
|
Weekly | • | III |
|
| |
| • Drain and clean Pasta Cooker |
|
|
|
|
Monthly | • Verify thermostat settings | IV & V |
| (primary and secondary) |
|
|
|
|
Yearly | QUALIFIED SERVICE | IV & V |
| PERSONNEL ONLY |
|
| • Disassemble Pasta Cooker to |
|
| clean burners, orifices and |
|
| runner pilot tube. |
|
| • Check and replace radiants. |
|
| • Align burners |
|
|
|
|
* High production facilities should be checked more often.
NOTE: Use of sodium chloride (salt) during the cooking process will have a detrimental effect on the cooker vessel and will void the warranty.
LIMITED CALIBRATION
Calibration is not covered under warranty
A. Calibration
NOTE: This procedure can only be used with the primary (left side) thermostat. When calibrating the secondary (right side) thermostat.
You will need:
One standard flat blade screwdriver.
One accurate thermometer suitable for boiling water.
NOTE: For best results, water should be clean.
1.Set thermostat to 212°F(190°C).
2.Allow Pasta System to cycle three times.
3.Place an accurate thermometer in the water.
Figure
NOTE: Locate thermometer in same position for every calibration. Position near primary thermostat (center) bulb is recommended.
4.If calibration of thermostat is found to be less than
Figure
Thermostat calibration
B.The Water Auto-Fill and Low Water Safety Shut- Off Systems
The water supply connection, located at the bottom rear of the Pasta System and marked water, is a standard 3/8” female pipe connection. The water pressure should be between
CAUTION
Connections suitable for hot water must be used. All connections must be tested for leaks before using the Pasta System.
NOTE: For Pasta Systems with casters, flexible hose must be used to avoid leaking when the Pasta System is moved for cleaning.
Control of the water level is fully automatic with the
10