Keating Of Chicago Gas Custom Pasta System manual Problem, SOLUTIONS Follow Sequentially

Page 17

PROBLEM

SOLUTIONS (Follow Sequentially)

 

 

Water always filling.

a.Clean sensors thoroughly with brush and vinegar.

 

b.Adjust the sensitivity of the B Board (for the top sensor) fully clockwise.

 

c. If filling persists, ground out the top sensor (if filling stops, replace sensor –

 

Part #010212).

 

d.If filling persists after grounding out the sensor, replace the B Board (Part

 

#001166)

 

 

Water never fills.

a.Turn water switch (far right) ‘ON.’

 

b.Clean sensors thoroughly with brush and vinegar.

 

c.Adjust the sensitivity of the B Board (for the top sensor) fully

 

counterclockwise (follow instructions on sheet).

 

d.Remove the wire from the top sensor. If filling begins, replace the sensor

 

(Part #010212).

 

e.If water does not fill, place a jumper wire across terminals A & C on the B

 

Board. If filling begins, replace B Board (Part #001166).

 

f. If water does not fill, replace water solenoid (Part #008133).

 

 

Runner bar will not light.

a.Remove and clean the flame switch bulb in the runner bar, enabling it to get

 

red hot.

 

b. Reposition flame switch bulb in the runner bar, enabling it to get red hot.

 

c.Replace flame switch (Part #004311)

 

 

Timers counting down in the

a.Reset the timer (see instructions on page 9)

wrong mode (Not minutes and

 

seconds).

 

 

 

Water leaking in the rear of the

a.Replace fill hose (Part #033495 – Sold per foot)

Custom Pasta System.

 

 

 

Burners won't come on (gas

a.Verify operating instructions in this manual (See page 9)

runner bar may be lit).

b.Clean the sensors with brush and vinegar.

 

 

c.Adjust sensitivity of the A Board (for the lower sensor) fully

 

counterclockwise (follow instruction sheet).

 

d.Place the wire attached to the lower sensor to ground. If heating begins,

 

replace the sensor (Part #010212).

 

e.If heating does not begin, place a jumper wire across terminals A & C on

 

the A Board. If heating begins, replace the A Board (Part #001167).

 

 

Unit is out of power.

a.Check electrical connection.

 

b.Check fuses.

 

c.Check Hi-Limit control.

 

 

Unit is powered, runner bar

a.Check gas connection.

cannot be started.

b.Check the gas valve.

 

 

c.Check the spark ignition electrode and spark ignition module if there is no

 

spark on the electrode.

 

 

Runner tube is starting, but

a.Clean flame sensor switch.

cannot hold the flame.

b.Check electrical connection to the flame switch.

 

 

c.(spark ignition only) Check spark ignition electrode.

 

d.(spark ignition only) Check electrical grounding.

 

 

 

 

14

Image 17
Contents Gas Pasta 0107 9/07 KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL1-800-KEATING POST THIS LABEL IN A PROMINENT LOCATION ON YOUR UNIT SECTION II INSTALLATION TABLE OF CONTENTSSECTION IV MAINTENANCE SECTION V SERVICE DIAGNOSISSTANDARD FEATURES I INTRODUCTIONSTANDARD ACCESSORIES SAFETY PRECAUTIONSCLEARANCES INSTALLATION II INSTALLATIONPOSITIONING CLEARANCES DAMAGE DURING SHIPMENTRESTRAINING DEVICES SPECIFICATIONSGAS CONNECTION HAVE YOUR PLUMBER OR GAS COMPANY CHECK FOR LEAKSELECTRICAL CONNECTION GAS LEAK TESTINGCHECK GAS SUPPLY PRESSURE SPECIAL NOTICESCALIBRATION III OPERATINGWATER AND DRAIN CONNECTIONS FILLINGCOOKING INDICATING LIGHTSSHUTDOWN DRAININGELECTRONIC TIMERS CLEANINGDisconnect electric power source before cleaning A. Timer OperationELECTRONIC TIMER OPERATING INSTRUCTIONS PART # IV MAINTENANCEWARRANTY REPAIRS B. How to program the “Keating” Electronic TimerPREVENTIVE MAINTENANCE CHART PREVENTIVE MAINTENANCEB. The Water Auto-Fill and Low Water Safety Shut- Off Systems LIMITED CALIBRATIONUsing a worn brush could damage the sensors PROBABLE CAUSE PROBLEMSOLUTION PROBABLE CAUSE SOLUTIONS Follow Sequentially REPLACEMENT OF A AND B BOARDS CUSTOM PASTA SYSTEM CONTROL PANEL WITH DIGITAL TIMERS V SERVICE DIAGNOSISMANUAL FILL CUSTOM PASTA SYSTEM CONTROL PANEL WITH DIGITAL TIMERS PART# GAS PASTA SYSTEM ASSEMBLYMODELS DESCRIPTION PASTA SYSTEM WIRING DIAGRAM GAS PASTA SYSTEM WITH BASKET-LIFT WIRING DIAGRAM KEATING WARRANTYThe Customer must provide proof of purchase from Keating If you have a service related question call 1-800-KEATING SERVICE INFORMATIONHave your serial and model number available when ordering parts “Serving Those Who Serve The Very Best”