PROBLEM | SOLUTIONS (Follow Sequentially) |
|
|
Water always filling. | a.Clean sensors thoroughly with brush and vinegar. |
| b.Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. |
| c. If filling persists, ground out the top sensor (if filling stops, replace sensor – |
| Part #010212). |
| d.If filling persists after grounding out the sensor, replace the B Board (Part |
| #001166) |
|
|
Water never fills. | a.Turn water switch (far right) ‘ON.’ |
| b.Clean sensors thoroughly with brush and vinegar. |
| c.Adjust the sensitivity of the B Board (for the top sensor) fully |
| counterclockwise (follow instructions on sheet). |
| d.Remove the wire from the top sensor. If filling begins, replace the sensor |
| (Part #010212). |
| e.If water does not fill, place a jumper wire across terminals A & C on the B |
| Board. If filling begins, replace B Board (Part #001166). |
| f. If water does not fill, replace water solenoid (Part #008133). |
|
|
Runner bar will not light. | a.Remove and clean the flame switch bulb in the runner bar, enabling it to get |
| red hot. |
| b. Reposition flame switch bulb in the runner bar, enabling it to get red hot. |
| c.Replace flame switch (Part #004311) |
|
|
Timers counting down in the | a.Reset the timer (see instructions on page 9) |
wrong mode (Not minutes and |
|
seconds). |
|
|
|
Water leaking in the rear of the | a.Replace fill hose (Part #033495 – Sold per foot) |
Custom Pasta System. |
|
|
|
Burners won't come on (gas | a.Verify operating instructions in this manual (See page 9) |
runner bar may be lit). | b.Clean the sensors with brush and vinegar. |
| |
| c.Adjust sensitivity of the A Board (for the lower sensor) fully |
| counterclockwise (follow instruction sheet). |
| d.Place the wire attached to the lower sensor to ground. If heating begins, |
| replace the sensor (Part #010212). |
| e.If heating does not begin, place a jumper wire across terminals A & C on |
| the A Board. If heating begins, replace the A Board (Part #001167). |
|
|
Unit is out of power. | a.Check electrical connection. |
| b.Check fuses. |
| c.Check |
|
|
Unit is powered, runner bar | a.Check gas connection. |
cannot be started. | b.Check the gas valve. |
| |
| c.Check the spark ignition electrode and spark ignition module if there is no |
| spark on the electrode. |
|
|
Runner tube is starting, but | a.Clean flame sensor switch. |
cannot hold the flame. | b.Check electrical connection to the flame switch. |
| |
| c.(spark ignition only) Check spark ignition electrode. |
| d.(spark ignition only) Check electrical grounding. |
|
|
|
|
14