Keating Of Chicago Gas Custom Pasta System manual V Service Diagnosis

Page 19
V SERVICE DIAGNOSIS

V SERVICE DIAGNOSIS

￿The burners when on will produce clear blue flames directed at the inside walls of the heat transfer tubes. The radiant’s fins, located towards the rear of each transfer tube, will glow bright red, helping to ensure optimum heat distribution into the Pasta System vessel. All radiants should be pushed to the rear and then pulled gently forward (until their retaining clips engage the rear of the tubes) for optimum heat distribution.

￿On constant pilot models, the pilot light will be between 3/8" to 1/2" high and will use about 180 BTU’s of gas per hour.

CUSTOM PASTASYSTEM CONTROL PANEL WITH DIGITAL TIMERS

ITEM

DESCRIPTION

QUANTITY

PART NUMBER

1

THERMOSTAT

2

031466

2

DIGITAL TIMER(S)

2

056921

3

TOGGLE SWITCH

1

004501

4

INDICATING LIGHT, AMBER - PILOT ON

1

031624

5

INDICATING LIGHT, GREEN - SECONDARY BURNER ON

1

009375

6

INDICATING LIGHT, BLUE - AUTOMATIC FILL

1

009256

7

MANUAL FILL SWITCH

1

004304

8

TOGGLE SWITCH - MAIN ON-OFF

2

004499

9

DIAL PLATE

2

034975

10

KNOB

2

004163

11

FLAME SWITCH (NOT SHOWN)

1

037406

12

LOW WATER SAFETY CONTROL “A” BOARD (NOT SHOWN)

1

001167

13

AUTOMATIC WATER FILL CONTROL “B” BOARD (NOT SHOWN)

1

001166

 

 

 

 

16

Image 19
Contents 1-800-KEATING KEEP THIS MANUAL FOR TRAINING NEW PERSONNELGas Pasta 0107 9/07 POST THIS LABEL IN A PROMINENT LOCATION ON YOUR UNIT SECTION V SERVICE DIAGNOSIS TABLE OF CONTENTSSECTION II INSTALLATION SECTION IV MAINTENANCESAFETY PRECAUTIONS I INTRODUCTIONSTANDARD FEATURES STANDARD ACCESSORIESCLEARANCES DAMAGE DURING SHIPMENT II INSTALLATIONINSTALLATION POSITIONING CLEARANCESHAVE YOUR PLUMBER OR GAS COMPANY CHECK FOR LEAKS SPECIFICATIONSRESTRAINING DEVICES GAS CONNECTIONSPECIAL NOTICES GAS LEAK TESTINGELECTRICAL CONNECTION CHECK GAS SUPPLY PRESSUREFILLING III OPERATINGCALIBRATION WATER AND DRAIN CONNECTIONSDRAINING INDICATING LIGHTSCOOKING SHUTDOWNA. Timer Operation CLEANINGELECTRONIC TIMERS Disconnect electric power source before cleaningB. How to program the “Keating” Electronic Timer IV MAINTENANCEELECTRONIC TIMER OPERATING INSTRUCTIONS PART # WARRANTY REPAIRSLIMITED CALIBRATION PREVENTIVE MAINTENANCEPREVENTIVE MAINTENANCE CHART B. The Water Auto-Fill and Low Water Safety Shut- Off SystemsUsing a worn brush could damage the sensors SOLUTION PROBLEMPROBABLE CAUSE SOLUTION SOLUTIONS Follow Sequentially REPLACEMENT OF A AND B BOARDS CUSTOM PASTA SYSTEM CONTROL PANEL WITH DIGITAL TIMERS V SERVICE DIAGNOSISMANUAL FILL CUSTOM PASTA SYSTEM CONTROL PANEL WITH DIGITAL TIMERS MODELS GAS PASTA SYSTEM ASSEMBLYPART# PART# PASTA SYSTEM WIRING DIAGRAM GAS PASTA SYSTEM WITH BASKET-LIFT WIRING DIAGRAM The Customer must provide proof of purchase from Keating WARRANTYKEATING “Serving Those Who Serve The Very Best” SERVICE INFORMATIONIf you have a service related question call 1-800-KEATING Have your serial and model number available when ordering parts