Makita EG381AE, EG301A, EG711AE, EG781AE, EG511AE manual Battery Charging Procedures, - 19-

Page 24

Battery Charging Procedures :

1)Stop engine.

2)Remove all connections from battery.

3)Insert the plug of exclusive DC cable into DC receptacle.

4)Connect positive (red) clip of DC cable to positive (+) terminal on battery, and then connect negative (black) clip of DC cable to negative (-) terminal on battery.

5)Take out all plugs at the battery electrolyte fluid filler ports.

6)Check the electrolyte fluid level, and refill the distilled water as necessary.

7)Start engine.

8)Make sure that the pilot lamp is turned on.

9)Make sure that the DC circuit breaker is in the ON position.

10) Battery charging will be started.

CAUTION

Do not use both AC and DC output at the same time.

Install correct positive (red) or negative (black) cable to the correct polarity on the battery.

Connect and disconnect DC cable with engine stopped.

An explosive hydrogen gas is discharged through vent holes in the battery during the charging process.

Do not allow spark or open flame around the generator or battery during the charging process.

Electrolyte fluid contains sulphuric acid, and so the fluid can burn eyes and clothing. Be extremely careful to avoid contact.

If injured, wash the affected area immediately with large quantities of water and consult a doctor for treatment.

Charging time is varied according to the kind of battery and discharged level of battery.

Measure the specific gravity of electrolyte fluid by means of hydrometer every one hour during battery charging.

Make sure if the DC circuit breaker is not turned off.

Battery charging is completed when the specific gravity is in the range of 1.26 to 1.28.

ENGLISH

19

Image 24
Contents EG series AIR Index Page Foreword [CAUTION]Contents Safety Precautions - 1-- 2- Specifications - 3-Components - 4-EG711A, EG711AE, EG781A, EG781AE - 5-- 6- PRE-OPERATION Checks Check Engine OIL- 7- Check Engine Fuel Up to Level position- 8- Checking Component Parts Check Generator Surroundings- 9- Grounding Generator Cable firstTo positive + terminal - 10-Operating Procedures Starting the Generator- 11- Recoil starter model Electric starter model- 13- Using Electric Power - 14-To take power out from the Twist - 15-Gfci Receptacle - 16-Full Power Switch Except EG301A - 17-Only for charging 12 volt battery DC Circuit BreakerConnection of exclusive DC cable - 18-Battery Charging Procedures - 19-Stopping the Generator OIL Sensor[Recoil starter model] [Electric starter model]Wattage Information - 21-Voltage Drop in Electric Extension Cords - 22-Spark Arrester - 23-Maintenance Schedule Periodic MaintenanceDaily Inspection - 24-Periodic Maintenance Schedule table - 25-HOW-TO Maintenance Servicing the AIR CleanerEngine OIL Change - 26-Cleaning and Adjusting Spark Plug Cleaning Fuel Strainer- 27- Checking Carbon Brush - 28-Disassembly - 29-Preparation for Storage - 30-Troubleshooting When Engine Fails to StartWhen No Electricity Is Generated at Receptacle - 31-Wiring Diagram EG301A 60Hz-120V- 32- EG381A 60Hz-120/240V - 33-EG381AE 60Hz-120/240V Grn/Y Earth Ground terminalEG511A, EG711A, EG781A 60Hz-120/240V - 35-EG511AE, EG711AE, EG781AE 60Hz-120/240V - 36-Makita Corporation