9. "HOW-TO" MAINTENANCE

ENGINE OIL CHANGE

Change engine oil every 100 hours. (For new engine, change oil after 20 hours.)

(a)Drain oil by removing the drain plug and the oil filler cap while the engine is warm.

Oil drain plug

(b)Reinstall the drain plug and fill the engine with oil until it reaches the upper level on the oil filler cap.

Use fresh and high quality lubricating oil to the specified level as directed on page 7. If contaminated or deteriorated oil is used or the quantity of the engine oil is not sufficient, the engine damage will result and its life will be greatly shortened.

SERVICING THE AIR CLEANER

Maintaining an air cleaner in proper condition is very important.

Dirt induced through improperly installed, improperly serviced or inadequate elements damages and wears out engines. Keep the element always clean.

(a)Remove the bolt of air cleaner cover. (EG711A, EG711AE, EG781A, EG781AE) Remove the air cleaner cover and cleaner element.

(b)Urethane form : Wash urethane form element in kerosene or diesel fuel. Then saturate the element in a mixture of 3 parts kerosene or diesel fuel and 1 part engine oil.

Squeeze the element to remove the mixture and install it in the air cleaner.

NOTE :

Instead of washing oil (kerosene), it is possible to wash the urethane foam element in a solution of mild detergent and warm water.

Then rinse the element thoroughly in clean water.

Allow the element to dry thoroughly. Soak the element in clean engine oil and squeeze out excess oil.

EG301A, EG381A, EG381AE

EG511A, EG511AE

Element

Element

 

Base

Base

 

Air cleaner

Air cleaner

cover

cover

 

EG711A, EG711AE

EG781A, EG781AE

Element Bolt Base

Air cleaner cover

26

Image 31
Contents EG series AIR Index Page [CAUTION] ForewordContents - 1- Safety Precautions- 2- - 3- Specifications- 4- Components- 5- EG711A, EG711AE, EG781A, EG781AE- 6- Check Engine OIL PRE-OPERATION Checks- 7- Up to Level position Check Engine Fuel- 8- Check Generator Surroundings Checking Component Parts- 9- - 10- Grounding GeneratorCable first To positive + terminalStarting the Generator Operating Procedures- 11- Electric starter model Recoil starter model- 13- - 14- Using Electric Power- 15- To take power out from the Twist- 16- Gfci Receptacle- 17- Full Power Switch Except EG301A- 18- Only for charging 12 volt batteryDC Circuit Breaker Connection of exclusive DC cable- 19- Battery Charging Procedures[Electric starter model] Stopping the GeneratorOIL Sensor [Recoil starter model]- 21- Wattage Information- 22- Voltage Drop in Electric Extension Cords- 23- Spark Arrester- 24- Maintenance SchedulePeriodic Maintenance Daily Inspection- 25- Periodic Maintenance Schedule table- 26- HOW-TO MaintenanceServicing the AIR Cleaner Engine OIL ChangeCleaning Fuel Strainer Cleaning and Adjusting Spark Plug- 27- - 28- Checking Carbon Brush- 29- Disassembly- 30- Preparation for Storage- 31- TroubleshootingWhen Engine Fails to Start When No Electricity Is Generated at ReceptacleEG301A 60Hz-120V Wiring Diagram- 32- - 33- EG381A 60Hz-120/240VGrn/Y Earth Ground terminal EG381AE 60Hz-120/240V- 35- EG511A, EG711A, EG781A 60Hz-120/240V- 36- EG511AE, EG711AE, EG781AE 60Hz-120/240VMakita Corporation