STOPPING THE GENERATOR
(a)Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator.
(b)Turn the AC circuit breaker to the "OFF" position.
(c)Allow the engine about 3 minutes to cool down at
(d)[Recoil starter model]
Turn the engine switch to the position "OFF".
[Electric starter model]
Turn the key switch to the STOP position.
(e) Close the fuel valve.
OFF
STOP
STOP
ON
OFF
ON
OFF
RUN
RUN |
|
ST | START |
ART |
OIL SENSOR
(a)The oil sensor detects the fall in oil level in the crankcase and automati- cally stops the engine when the oil level falls below a predetermined level.
(b)When engine has stopped automatically, switch off generator's AC circuit breaker, and check the oil level.
Refill engine oil to the upper level as instructed on page 7 and restart the engine.
(c)If the engine does not start by usual starting procedures, check the oil level.
CLOSE |
CLOSE |
OPEN |
Oil sensor