STOPPING THE GENERATOR

(a)Turn off the power switch of the electric equipment and unplug the cord from receptacle of the generator.

(b)Turn the AC circuit breaker to the "OFF" position.

(c)Allow the engine about 3 minutes to cool down at no-load before stopping.

(d)Recoil starter model

Turn the engine switch to the position "OFF".

Electric starter model

Turn the key switch to the STOP position.

(e) Close the fuel valve.

OFF

STOP

STOP

ON

OFF

ON

OFF

RUN

RUN

 

ST

START

ART

OIL SENSOR

(a)The oil sensor detects the fall in oil level in the crankcase and automati- cally stops the engine when the oil level falls below a predetermined level.

(b)When engine has stopped automatically, switch off generator's AC circuit breaker, and check the oil level.

Refill engine oil to the upper level as instructed on page 7 and restart the engine.

(c)If the engine does not start by usual starting procedures, check the oil level.

CLOSE

CLOSE

OPEN

Oil sensor

20

Image 25
Contents EG series AIR Index Page [CAUTION] ForewordContents - 1- Safety Precautions- 2- - 3- Specifications- 4- Components- 5- EG711A, EG711AE, EG781A, EG781AE- 6- Check Engine OIL PRE-OPERATION Checks- 7- Up to Level position Check Engine Fuel- 8- Check Generator Surroundings Checking Component Parts- 9- Cable first Grounding GeneratorTo positive + terminal - 10-Starting the Generator Operating Procedures- 11- Electric starter model Recoil starter model- 13- - 14- Using Electric Power- 15- To take power out from the Twist- 16- Gfci Receptacle- 17- Full Power Switch Except EG301ADC Circuit Breaker Only for charging 12 volt batteryConnection of exclusive DC cable - 18-- 19- Battery Charging ProceduresOIL Sensor Stopping the Generator[Recoil starter model] [Electric starter model]- 21- Wattage Information- 22- Voltage Drop in Electric Extension Cords- 23- Spark ArresterPeriodic Maintenance Maintenance ScheduleDaily Inspection - 24-- 25- Periodic Maintenance Schedule tableServicing the AIR Cleaner HOW-TO MaintenanceEngine OIL Change - 26-Cleaning Fuel Strainer Cleaning and Adjusting Spark Plug- 27- - 28- Checking Carbon Brush- 29- Disassembly- 30- Preparation for StorageWhen Engine Fails to Start TroubleshootingWhen No Electricity Is Generated at Receptacle - 31-EG301A 60Hz-120V Wiring Diagram- 32- - 33- EG381A 60Hz-120/240VGrn/Y Earth Ground terminal EG381AE 60Hz-120/240V- 35- EG511A, EG711A, EG781A 60Hz-120/240V- 36- EG511AE, EG711AE, EG781AE 60Hz-120/240VMakita Corporation