Makita EG511A, EG781A, EG711A, EG301A Only for charging 12 volt battery, DC Circuit Breaker, - 18-

Page 23

(2)DC APPLICATION

(Only for charging 12 volt battery)

DC receptacle (Only for charging 12 volt battery)

For charging 12 voltage battery, 12V-8.3A (100W) of maximum AC power can be taken out from the DC receptacle by means of the exclusive DC cable.

The exclusive DC cable is come with your generator set (included in the package).

 

BLACK

 

CABLE

RED

 

CABLE

-

 

+

DC receptacle

DC Circuit Breaker

DC circuit breaker is turned off to shut down the DC power, when the DC is over the usage range or the battery is defective.

Check the generator and/or battery for overloading or defect, and turn on the DC circuit breaker after no problem and defect are found out.

Connection of exclusive DC cable :

Connect positive (red) clip of DC cable to positive (+) terminal on battery.

Connect negative (black) clip of DC cable to negative (-) terminal on battery.

18

Image 23
Contents EG series AIR Index Page [CAUTION] ForewordContents - 1- Safety Precautions- 2- - 3- Specifications- 4- Components- 5- EG711A, EG711AE, EG781A, EG781AE- 6- - 7- PRE-OPERATION ChecksCheck Engine OIL - 8- Check Engine FuelUp to Level position - 9- Checking Component PartsCheck Generator Surroundings - 10- Grounding GeneratorCable first To positive + terminal- 11- Operating ProceduresStarting the Generator Electric starter model Recoil starter model- 13- - 14- Using Electric Power- 15- To take power out from the Twist- 16- Gfci Receptacle- 17- Full Power Switch Except EG301A- 18- Only for charging 12 volt batteryDC Circuit Breaker Connection of exclusive DC cable- 19- Battery Charging Procedures[Electric starter model] Stopping the GeneratorOIL Sensor [Recoil starter model]- 21- Wattage Information- 22- Voltage Drop in Electric Extension Cords- 23- Spark Arrester- 24- Maintenance SchedulePeriodic Maintenance Daily Inspection- 25- Periodic Maintenance Schedule table- 26- HOW-TO MaintenanceServicing the AIR Cleaner Engine OIL Change- 27- Cleaning and Adjusting Spark PlugCleaning Fuel Strainer - 28- Checking Carbon Brush- 29- Disassembly- 30- Preparation for Storage- 31- TroubleshootingWhen Engine Fails to Start When No Electricity Is Generated at Receptacle- 32- Wiring DiagramEG301A 60Hz-120V - 33- EG381A 60Hz-120/240VGrn/Y Earth Ground terminal EG381AE 60Hz-120/240V- 35- EG511A, EG711A, EG781A 60Hz-120/240V- 36- EG511AE, EG711AE, EG781AE 60Hz-120/240VMakita Corporation