10. PREPARATION FOR STORAGE

The following procedures should be followed prior to storage of your generator for periods of 6 months or longer.

Drain fuel from fuel tank carefully by disconnecting the fuel line. Gasoline left in the fuel tank will eventually deteriorate making engine- starting difficult.

Remove the carburetor float chamber and also drain the carburetor.

Change engine oil.

Check for loose bolts and screws, tighten them if necessary.

Drain screw

Clean generator thoroughly with oiled cloth. Spray with preservative if available. NEVER USE WATER TO CLEAN GENERATOR !

Pull starter handle until resistance is felt, leaving handle in that position.

Store generator in a well ventilated, low humidity area.

30

Image 35
Contents EG series AIR Index Page [CAUTION] ForewordContents - 1- Safety Precautions- 2- - 3- Specifications- 4- Components- 5- EG711A, EG711AE, EG781A, EG781AE- 6- - 7- PRE-OPERATION ChecksCheck Engine OIL - 8- Check Engine FuelUp to Level position - 9- Checking Component PartsCheck Generator Surroundings - 10- Grounding GeneratorCable first To positive + terminal- 11- Operating ProceduresStarting the Generator Electric starter model Recoil starter model- 13- - 14- Using Electric Power- 15- To take power out from the Twist- 16- Gfci Receptacle- 17- Full Power Switch Except EG301A- 18- Only for charging 12 volt batteryDC Circuit Breaker Connection of exclusive DC cable- 19- Battery Charging Procedures[Electric starter model] Stopping the GeneratorOIL Sensor [Recoil starter model]- 21- Wattage Information- 22- Voltage Drop in Electric Extension Cords- 23- Spark Arrester- 24- Maintenance SchedulePeriodic Maintenance Daily Inspection- 25- Periodic Maintenance Schedule table- 26- HOW-TO MaintenanceServicing the AIR Cleaner Engine OIL Change- 27- Cleaning and Adjusting Spark PlugCleaning Fuel Strainer - 28- Checking Carbon Brush- 29- Disassembly- 30- Preparation for Storage- 31- TroubleshootingWhen Engine Fails to Start When No Electricity Is Generated at Receptacle- 32- Wiring DiagramEG301A 60Hz-120V - 33- EG381A 60Hz-120/240VGrn/Y Earth Ground terminal EG381AE 60Hz-120/240V- 35- EG511A, EG711A, EG781A 60Hz-120/240V- 36- EG511AE, EG711AE, EG781AE 60Hz-120/240VMakita Corporation