Makita EG511A, EG781A, EG711A, EG301A Checking Component Parts, Check Generator Surroundings, - 9-

Page 14

CHECKING COMPONENT PARTS

Check following items before starting engine:

Fuel leakage from fuel hose, etc.

Bolts and nuts for looseness.

Components for damage or breakage.

Generator not resting on or against any adjacent wiring.

CHECK GENERATOR SURROUNDINGS

WARNING

Make sure you review each warning in order to prevent fire hazard.

Keep area clear of in flammables or other hazardous materials.

Keep generator at least 3 feet (1 meter) away from buildings or other structures.

Only operate generator in a dry, well ventilated area.

Keep exhaust pipe clear of foreign objects.

Keep generator away from open flame. No smoking!

Keep generator on a stable and level surface.

Do not block generator air vents with paper or other material.

ENGLISH

BATTERY INSTALLATION (Electric Starter Model)

Recommended Battery

Type

; Lead-acid battery

 

 

Capacity (Ah/5hr) ; 12V-21AH or more

 

 

Size

; Less than 185(L) x 125(W) x 160(H) mm

Earth Cable(BLACK)

Setting Plate

Bolt

Protection Plate

 

 

 

Nut

 

 

 

 

 

Battery Frame #1

Bolt

Starter Cable(RED)

 

 

 

 

Bolt

Nut

 

 

 

 

 

 

 

Setting Bolt

 

 

 

 

 

 

 

 

 

Bolt

 

Nut

 

 

 

 

 

Bolt

 

Battery Plate

Battery Frame #2

 

 

 

 

9

 

 

Image 14
Contents EG series AIR Index Page Foreword [CAUTION]Contents Safety Precautions - 1-- 2- Specifications - 3-Components - 4-EG711A, EG711AE, EG781A, EG781AE - 5-- 6- - 7- PRE-OPERATION ChecksCheck Engine OIL - 8- Check Engine FuelUp to Level position - 9- Checking Component PartsCheck Generator Surroundings To positive + terminal Grounding GeneratorCable first - 10-- 11- Operating ProceduresStarting the Generator Recoil starter model Electric starter model- 13- Using Electric Power - 14-To take power out from the Twist - 15-Gfci Receptacle - 16-Full Power Switch Except EG301A - 17-Connection of exclusive DC cable Only for charging 12 volt batteryDC Circuit Breaker - 18-Battery Charging Procedures - 19-[Recoil starter model] Stopping the GeneratorOIL Sensor [Electric starter model]Wattage Information - 21-Voltage Drop in Electric Extension Cords - 22-Spark Arrester - 23-Daily Inspection Maintenance SchedulePeriodic Maintenance - 24-Periodic Maintenance Schedule table - 25-Engine OIL Change HOW-TO MaintenanceServicing the AIR Cleaner - 26-- 27- Cleaning and Adjusting Spark PlugCleaning Fuel Strainer Checking Carbon Brush - 28-Disassembly - 29-Preparation for Storage - 30-When No Electricity Is Generated at Receptacle TroubleshootingWhen Engine Fails to Start - 31-- 32- Wiring DiagramEG301A 60Hz-120V EG381A 60Hz-120/240V - 33-EG381AE 60Hz-120/240V Grn/Y Earth Ground terminalEG511A, EG711A, EG781A 60Hz-120/240V - 35-EG511AE, EG711AE, EG781AE 60Hz-120/240V - 36-Makita Corporation