8. MAINTENANCE SCHEDULE

MAINTENANCE, REPLACEMENT, OR REPAIR OF THE EMISSION CONTROL DEVICES AND SYSTEMS MAY BE PERFORMED BY ANY NONROAD ENGINE REPAIR ESTABLISHMENT OR INDIVIDUAL.

DAILY INSPECTION

Before running the generator, check the following service items:

Enough gasoline

Excessive vibration,noise

Enough clean engine oil

Loose or broken bolts and nuts

Leakage of gasoline and engine oil

Safe surroundings

Clean air cleaner element

PERIODIC MAINTENANCE

Periodic maintenance is vital to safe and efficient operation of your generator. Check the table below for periodic maintenance intervals.

IT IS ALSO NECESSARY FOR THE USER OF THIS GENERATOR TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION- RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFECTIVE.

The emission control system consists of the following parts :

(1)

Carburetor and internal

(4)

Air cleaner elements

(8) Exhaust manifold, if

 

parts

(5)

Spark plug

applicable

 

 

 

(2)

Cold start enrichment

(6)

Magneto or electronic

(9) Hoses, belts,

 

system, if applicable

connectors, and

 

 

ignition system

 

 

 

assemblies

(3)

Intake manifold, if

(7)

Spark advance/retard

 

 

 

 

applicable

system, if applicable

 

The maintenance schedule indicated in the table is based on the normal generator operation. Should the generator be operated in extremely dusty condition or in heavier loading condition, the maintenance intervals must be shortened depending on the contamination of oil, clogging of filter elements, wear of parts, and so on.

24

Image 29
Contents EG series AIR Index Page [CAUTION] ForewordContents - 1- Safety Precautions- 2- - 3- Specifications- 4- Components- 5- EG711A, EG711AE, EG781A, EG781AE- 6- - 7- PRE-OPERATION ChecksCheck Engine OIL - 8- Check Engine FuelUp to Level position - 9- Checking Component PartsCheck Generator Surroundings Cable first Grounding GeneratorTo positive + terminal - 10-- 11- Operating ProceduresStarting the Generator Electric starter model Recoil starter model- 13- - 14- Using Electric Power- 15- To take power out from the Twist- 16- Gfci Receptacle- 17- Full Power Switch Except EG301ADC Circuit Breaker Only for charging 12 volt batteryConnection of exclusive DC cable - 18-- 19- Battery Charging ProceduresOIL Sensor Stopping the Generator[Recoil starter model] [Electric starter model]- 21- Wattage Information- 22- Voltage Drop in Electric Extension Cords- 23- Spark ArresterPeriodic Maintenance Maintenance ScheduleDaily Inspection - 24-- 25- Periodic Maintenance Schedule tableServicing the AIR Cleaner HOW-TO MaintenanceEngine OIL Change - 26-- 27- Cleaning and Adjusting Spark PlugCleaning Fuel Strainer - 28- Checking Carbon Brush- 29- Disassembly- 30- Preparation for StorageWhen Engine Fails to Start TroubleshootingWhen No Electricity Is Generated at Receptacle - 31-- 32- Wiring DiagramEG301A 60Hz-120V - 33- EG381A 60Hz-120/240VGrn/Y Earth Ground terminal EG381AE 60Hz-120/240V- 35- EG511A, EG711A, EG781A 60Hz-120/240V- 36- EG511AE, EG711AE, EG781AE 60Hz-120/240VMakita Corporation