Topcon COMPUTERIZED TONOMETER, CT-80 instruction manual Alignment and Measurement

Page 35

Alignment and Measurement

MEMO

It is recommended that you do intraocular pressure measure- ments several times. Since the intraocular pressure varies by heart beats and tears, often it is not possible to obtain exact measurement values by measuring only once or twice.

The alignment operation can be performed with the control lever.

Moving the machine body by the control lever

When the machine body needs to be moved slightly back and forth or right and left, move the control lever in each direction.

Operating the control lever (back and forth, right and left)

Never insert your fingers under the measuring head.

CAUTION Inform the patient of this, too.

Careless insertion of fingers may cause injury by pinching.

To move the measuring head vertically, turn the control lever right for raising and left for lowering.

Operating the control lever (up and down)

34

BASIC OPERATIONS

Image 35
Contents CT-80 Introduction This instrument features the followingDisplay Meaning Display for Safe USEIcons Prevention item Safety CautionsIcon Prevention item Safety CautionsPurpose Usage and MaintenanceUser Maintenance Escape ClausePage Names of Components ContentMain Body Components ComponentsControl Panel Components Auto/Manual switchAir check switch Measurement Screen Manual mode, alignment OK Menu Screen Monitor Screen ComponentsMeasurement Screen Auto mode, alignment Contents of Printer Output Standard Accessories Preparations HOW to Install the InstrumentHOW to Connect External I/O Terminals HOW to Connect the Power CableDisplaying The Menu Screen Initial SettingsMemo PreparationsTime/Date Setting Setting The Power Save Time RS-232C INPUT/OUTPUT Settings OFF ↔ MODE1 ↔ MODE2 ↔ MODE3 ↔ MODE4 ↔ Setting The Average Value Mode Setting The Buzzer Message Input Back HOW to SET Printer PaperAuto Setting StepPreparations TF50KS-E2C Manual Setting Preparations HOW to Reset from Power Save Status Air Check Turn on the PowerBasic Operations Preparations Before MeasurementSetting the Patient Setting the Safety Stopper ∼10mm Auto Measurement Under Auto Mode MemoSetting the Measurement Mode Setting the Measuring RangeAlignment and Measurement Basic Operations Basic Operations Manual mode. Sometimes Auto mode is not available if Manu Measurement Under Manual Mode MemoDisplay of Measurement Values ERR OverBasic Operations Alignment is adjusted correctly. Sometimes the shape Deleting Measurement Values Individual Operations HOW to Print OUT Measurement ValuesHOW to Correct Measurement Values Input via RS-232C INPUT/OUTPUT VIA RS-232COutput via RS-232C Checking Operations Before Requesting ServiceChecking Operations Automatic instrument table AIT-20 and Table Board Optional AccessoriesSpecifications & Performance ReferenceTerminal Pin Arrangement RS-232C Communication SpecificationsConnector Types Transmission Formula Contents of Data TransmissionReference Work ID no Setting RS-232C Communication ConditionsFormat Cleaning the Measuring Window Glass Maintenance and CheckingAccuracy Maintenance Cleaning the Window Glass inside the Nozzle Ordering Consumable Supplies Daily MaintenanceAdjusting the Monitor Screen Replacing the Fuse Paper Jam in PrinterCleaning the Outer Cover Special Notes on CleaningComputerized Tonometer CT-80 Topcon Omni SYSTEMS, INC Computerized Tonometer