Xantrex Technology XHR, XFR, XFR3 manual Specifications, Models 140 12-100 20-60 35-35 40-30, Ovp

Page 15

Features and Specifications

Specifications

Specifications

The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice.

Table 1.1 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (7.5 V to 40 V)

Models

7.5-140

12-100

20-60

35-35

40-30

Program Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

OVP

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Program Accuracy1

10mV

50mV

75mV

75mV

75mV

Voltage

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

OVP

80mV

150mV

200mV

350mV

400mV

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.4mV

6.2mV

Current

19.6mA

14mA

8.4mA

5.4mA

4.2mA

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

500mA

460mA

250mA

200mA

150mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.15%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-60 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

Release 3.1

13

Image 15
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Contents Description Features and SpecificationsReadback Features and FunctionsFeatures and Specifications FunctionsSpecifications Models 140 12-100 20-60 35-35 40-30OVP Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Basic Setup Procedure Step # Description Action ReferencePON SRQ Address IEEE-488 Primary Address SelectionPower On Service Request PON SRQ Rear Panel SRQ Switch Position PON SRQ StateSwitch Position Power on results Iset Condition Default Settings Model ExampleIbfind devname Internal PCB Jumper Selections IEEE-488 Controller ConnectionHigh LOW OFF High OFF LOWUser Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Gpib Operation OperationExample Ascii LSB Bit Decimal Description Reset By Position WeightRequest Service SRQ Set when Power On PON Set when unitCommand Syntax Computer EntryFormat Floating Number Definition Example Description FormIset 2.0A Vset Command Summary DLY? AUXA?AUXB? CMODE?IHI FAULT?Cmode IdataAuxb 1 on Command ReferenceCommand Description Auxa 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Voltage Voltage Mode CalibrationSetup Voltage Program Calibration Procedure ReadbackCalibration Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc