The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice.
Table 1.1 Specifications for XFR 1200 W Series Supply with GPIB Interface Installed (7.5 V to 40 V)
Models |
|
|
|
|
|
Program Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 5.4mV | 6.2mV |
Current | 19.6mA | 14mA | 8.4mA | 5.4mA | 4.2mA |
OVP | 1.16mV | 1.8mV | 3.08mV | 5.4mV | 6.2mV |
Program Accuracy1 | 10mV | 50mV | 75mV | 75mV | 75mV |
Voltage | |||||
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.3% |
Current | 500mA | 460mA | 250mA | 200mA | 150mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.15% |
OVP | 80mV | 150mV | 200mV | 350mV | 400mV |
Readback Resolution |
|
|
|
|
|
Voltage | 1.16mV | 1.8mV | 3.08mV | 5.4mV | 6.2mV |
Current | 19.6mA | 14mA | 8.4mA | 5.4mA | 4.2mA |
Readback Accuracy1 |
|
|
|
|
|
Voltage | 30mV | 60mV | 75mV | 75mV | 75mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.3% |
Current | 500mA | 460mA | 250mA | 200mA | 150mA |
| ±0.1% | ±0.1% | ±0.1% | ±0.1% | ±0.15% |
1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
Release 3.1 | 13 |