Xantrex Technology XHR, XFR, XFR3 manual Command Summary

Page 42

Operation

Command Summary

Command Summary

Use these commands to control the operation of the supply. They are listed here in order of function such as PROGRAMMING, QUERY, CALIBRATION, and STATUS commands. See “Command Reference” on page 43 for more detailed information about each command and its use.

Table 3.5

Programming Commands

Command

Description

 

 

AUXA

Selects the state of the AUXA output signal on the J7-7 connector.

 

 

AUXB

Selects the state of the AUXB output signal on the J7-8 connector.

 

 

CLR

Initializes the power supply to its Power ON (PON) state.

 

 

DLY

Sets a programmable time delay which is executed by the supply

 

before reporting fault conditions after a new output voltage or current is

 

specified.

FOLD

Sets foldback mode for the supply.

 

 

HOLD

Enables or disables voltage/current setting hold mode for the supply.

 

 

IMAX

Sets an upper soft limit on the programmed output current for the

 

supply.

 

 

ISET

Sets the output current of the supply in amps (default) or in milliamps.

 

 

OUT

Enables or disables voltage/current output for the supply.

 

 

OVSET

Sets the over voltage protection trip point for the supply in volts

 

(default) or in millivolts.

RST

Resets the supply to the present voltage and current settings if the

 

output is disabled by OVP or foldback protection.

 

 

SRQ

Enables or disables the power supply's ability to generate a service

 

request.

TRG

Implements programmed voltage and current settings which had been

 

in hold mode.

VMAX

Sets an upper soft limit on the supply’s programmed output voltage.

 

 

VSET

Sets the output voltage of the power supply in volts (default) or in

 

millivolts.

40

Operating Manual for GPIB for XHR/XFR Series Power Supply

Image 42
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Contents Features and Specifications DescriptionFunctions Features and FunctionsFeatures and Specifications ReadbackSpecifications Models 140 12-100 20-60 35-35 40-30OVP Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Introduction Initial InspectionInstallation and Configuration Initial InspectionGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Basic Setup Procedure Step # Description Action ReferencePON SRQ IEEE-488 Primary Address Selection AddressPower On Service Request PON SRQ Rear Panel SRQ Switch Position PON SRQ StateSwitch Position Power on results Condition Default Settings Model Example IsetIbfind devname IEEE-488 Controller Connection Internal PCB Jumper SelectionsHigh OFF LOW High LOW OFFUser Signals User Signals J7 ConnectorJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Operation Gpib OperationExample Ascii Power On PON Set when unit Bit Decimal Description Reset By Position WeightRequest Service SRQ Set when LSBCommand Syntax Computer EntryFormat Description Form Floating Number Definition ExampleIset 2.0A Vset Command Summary CMODE? AUXA?AUXB? DLY?Idata FAULT?Cmode IHIAuxa 1 on Command ReferenceCommand Description Auxb 1 onChanging an output setting Response Fold mode where mode is Snsp Mask None = Unmask ALLStatus, and Fault Registers on Accumulated Status, Status, and Fault Registers on SNSP, ALL, NoneResponse Vmax voltage Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit WeightError Codes 11 Error CodesTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Readback Voltage Mode CalibrationSetup VoltageCalibration Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc