Xantrex Technology XHR, XFR, XFR3 manual J7 User Signal Connector Circuit Block Diagram

Page 33

Installation and Configuration

User Signals

Figure 2.5

J7 User Signal Connector Circuit Block Diagram

J7 Cable Use a standard 8-position telephone jack and data cable to connect to J7. Add a Connection ferrite block to reduce radiated emission. The one inch square ferrite block with

built-in housing clip is packaged and shipped with the power supply interface card.

To install the ferrite block:

1.Position the block no more than 5 cm (2") from the power supply end of the J7 user cable.

2.Open the ferrite block housing.

3.Loop the cable through the ferrite block. See Figure 2.6, “J7 User Cable with Ferrite Block” on page 32.

4.Close the housing clip.

The ferrite block ensures that the power supply system meets radiated emission requirement 89/336/EEC for CE mark approval. See the power supply's operating manual for noise specifications.

Release 3.1

31

Image 33
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Contents Description Features and SpecificationsFeatures and Specifications Features and FunctionsFunctions ReadbackSpecifications Models 140 12-100 20-60 35-35 40-30OVP Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Basic Setup Procedure Step # Description Action ReferencePON SRQ Address IEEE-488 Primary Address SelectionPower On Service Request PON SRQ Rear Panel SRQ Switch Position PON SRQ StateSwitch Position Power on results Iset Condition Default Settings Model ExampleIbfind devname Internal PCB Jumper Selections IEEE-488 Controller ConnectionHigh LOW OFF High OFF LOWUser Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Gpib Operation OperationExample Ascii Request Service SRQ Set when Bit Decimal Description Reset By Position WeightPower On PON Set when unit LSBCommand Syntax Computer EntryFormat Floating Number Definition Example Description FormIset 2.0A Vset Command Summary AUXB? AUXA?CMODE? DLY?Cmode FAULT?Idata IHICommand Description Command ReferenceAuxa 1 on Auxb 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Readback VoltageCalibration Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc