Features and Specifications

Specifications

Table 1.4 Specifications for XFR 2800 W Series Supply with GPIB Interface Installed (60 V to 600 V)

Models

60-46

100-28

150-18

300-9

600-4

Program Resolution

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Voltage

Current

6.44mA

3.92mA

2.52mA

1.26mA

0.56mA

OVP

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Program Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

250mA

140mA

120mA

80mA

80mA

 

±0.1%

±0.15%

±0.1%

±0.1%

±0.1%

OVP

600mV

800mV

1.5V

3.0V

6V

Readback Resolution

 

 

 

 

 

Voltage

9.2mV

15.4mV

23.1mV

46.2mV

92.4mV

Current

6.44mA

3.92mA

2.52mA

1.26mA

0.56mA

Readback Accuracy1

 

 

 

 

 

Voltage

150mV

150mV

225mV

225mV

250mV

 

±0.25%

±0.35%

±0.35%

±0.35%

±0.35%

Current

250mA

140mA

120mA

80mA

80mA

 

±0.1%

±0.15%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts

16

Operating Manual for GPIB for XHR/XFR Series Power Supply

Image 18
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for How do you get service? Phone 604 422 Toll Free North America 800 667 Fax 604 421What does this warranty not cover? Disclaimer Product Information About Your Power Supply Model Number Serial Number Purchased From Purchase DateSafety SupplyMain Sections Manual RevisionsAbout This Manual Contents Contents Features and Specifications DescriptionFunctions Features and FunctionsFeatures and Specifications ReadbackSpecifications Models 140 12-100 20-60 35-35 40-30OVP Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Introduction Initial InspectionInstallation and Configuration Initial InspectionGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Basic Setup Procedure Step # Description Action ReferencePON SRQ IEEE-488 Primary Address Selection AddressPower On Service Request PON SRQ Rear Panel SRQ Switch Position PON SRQ StateSwitch Position Power on results Condition Default Settings Model Example IsetIbfind devname IEEE-488 Controller Connection Internal PCB Jumper SelectionsHigh OFF LOW High LOW OFFUser Signals User Signals J7 ConnectorJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Operation Gpib OperationExample Ascii Power On PON Set when unit Bit Decimal Description Reset By Position WeightRequest Service SRQ Set when LSBCommand Syntax Computer EntryFormat Description Form Floating Number Definition ExampleIset 2.0A Vset Command Summary CMODE? AUXA?AUXB? DLY?Idata FAULT?Cmode IHIAuxa 1 on Command ReferenceCommand Description Auxb 1 onChanging an output setting Response Fold mode where mode is Snsp Mask None = Unmask ALLStatus, and Fault Registers on Accumulated Status, Status, and Fault Registers on SNSP, ALL, NoneResponse Vmax voltage Accumulated Status, Status, and Fault Registers Condition Mnemonic Bit Position Bit WeightError Codes 11 Error CodesTroubleshooting LEDsCalibration Voltage Program Calibration Procedure Readback Voltage Mode CalibrationSetup VoltageCalibration Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc