Xantrex Technology XHR, XFR, XFR3 manual Models 300 12-220 20-130 33-85 40-70

Page 17

Features and Specifications

Specifications

Table 1.3 Specifications for XFR 2800 W Series Supply with GPIB Interface Installed (7.5 V to 40 V)

Models

7.5-300

12-220

20-130

33-85

40-70

Program Resolution

1.16mV

1.8mV

3.08mV

5.1mV

6.2mV

Voltage

Current

42.0mA

30.8mA

18.2mA

13.0mA

9.8mA

OVP

1.16mV

1.8mV

3.08mV

5.1mV

6.2mV

Program Accuracy1

 

 

 

 

 

Voltage

10mV

50mV

75mV

75mV

75mV

Current

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

900mA

750mA

500mA

425mA

350mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

OVP

80mV

150mV

200mV

330mV

400mV

Readback Resolution

 

 

 

 

 

Voltage

1.16mV

1.8mV

3.08mV

5.1mV

6.2mV

Current

42.0mA

30.8mA

18.2mA

13.0mA

9.8mA

Readback Accuracy1

 

 

 

 

 

Voltage

30mV

60mV

75mV

75mV

75mV

 

±0.12%

±0.12%

±0.12%

±0.3%

±0.3%

Current

900mA

750mA

500mA

425mA

350mA

 

±0.1%

±0.1%

±0.1%

±0.1%

±0.1%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model 20-130 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.

Release 3.1

15

Image 17
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Contents Description Features and SpecificationsFeatures and Specifications Features and FunctionsFunctions ReadbackOVP SpecificationsModels 140 12-100 20-60 35-35 40-30 Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB PON SRQ Basic Setup ProcedureStep # Description Action Reference Address IEEE-488 Primary Address SelectionSwitch Position Power on results Power On Service Request PON SRQRear Panel SRQ Switch Position PON SRQ State Iset Condition Default Settings Model ExampleIbfind devname Internal PCB Jumper Selections IEEE-488 Controller ConnectionHigh LOW OFF High OFF LOWUser Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Gpib Operation OperationExample Ascii Request Service SRQ Set when Bit Decimal Description Reset By Position WeightPower On PON Set when unit LSBFormat Command SyntaxComputer Entry Floating Number Definition Example Description FormIset 2.0A Vset Command Summary AUXB? AUXA?CMODE? DLY?Cmode FAULT?Idata IHICommand Description Command ReferenceAuxa 1 on Auxb 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Readback VoltageCalibration Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc