Xantrex Technology XHR, XFR, XFR3 manual Error Codes

Page 53

Operation

Error Codes

Error Codes

If the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an error number which corresponds to an event described in the following table. The ERR? query will also clear the ERR bit in the register.

Table 3.11 Error Codes

ERROR #

ERROR IDENTIFICATION

EXPLANATION

0

No Errors

 

 

 

 

4

Unrecognized Character

Received a character such as @,*,$.

 

 

 

 

Improper Number

Received a numeric character but the

 

 

characters were not a proper number.

 

 

Example: VSET,±10.3

 

Unrecognized String

Received an invalid command.

 

 

 

 

Syntax Error

Received an incorrectly placed word,

 

 

number, separator, or terminator.

 

 

Example: OFF SRQ, VOUT 6, MASK,

 

 

ERR

5

Number Out of Range

Specified a value for the command

 

 

which was outside of the allowed range.

 

 

 

6

Attempt to Exceed Soft Limits

Attempted to program a voltage or

 

 

current greater than the soft limit.

 

 

Example: VMAX 500; VSET 550 LF

 

 

 

7

Improper Soft Limit

Attempted to program a soft limit less

 

 

than the output value.

8

Data Requested without a

The controller requested data from the

 

Query Being Sent

power supply without first sending a

 

 

query command.

9

OVP Set Below Output

Sent an OVSET command with a trip

 

 

value lower than the output voltage.

10

Slave Processor Not

The interface PCB slave processor did

 

Responding

not respond.

 

 

 

12

Illegal Calibration

Attempted calibration when the supply

 

 

was not in calibration mode. See

 

 

CMODE command.

 

 

 

Release 3.1

51

Image 53
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Contents Description Features and SpecificationsFeatures and Specifications Features and FunctionsFunctions ReadbackOVP SpecificationsModels 140 12-100 20-60 35-35 40-30 Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB PON SRQ Basic Setup ProcedureStep # Description Action Reference Address IEEE-488 Primary Address SelectionSwitch Position Power on results Power On Service Request PON SRQRear Panel SRQ Switch Position PON SRQ State Iset Condition Default Settings Model ExampleIbfind devname Internal PCB Jumper Selections IEEE-488 Controller ConnectionHigh LOW OFF High OFF LOWUser Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Gpib Operation OperationExample Ascii Request Service SRQ Set when Bit Decimal Description Reset By Position WeightPower On PON Set when unit LSBFormat Command SyntaxComputer Entry Floating Number Definition Example Description FormIset 2.0A Vset Command Summary AUXB? AUXA?CMODE? DLY?Cmode FAULT?Idata IHICommand Description Command ReferenceAuxa 1 on Auxb 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Readback VoltageCalibration Current Program Calibration Procedure Current Mode CalibrationCurrent Calibration Setup Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc