Xantrex Technology XHR, XFR, XFR3 manual Features and Specifications, Description

Page 13

Section 1. Features and Specifications

Description

The internal GPIB interface card allows you to operate your power supply from a computer controller via the IEEE-488 communications bus. See Figure 1.1, “Sample Configuration using GPIB Interface”.

The GPIB interface allows complete remote programming of your power supply, including status reporting, settings query, and interrupt generation with user-designated fault conditions. Both the voltage and current output are precisely programmed directly in volts and amps with 16-bit resolution. Additionally, the built-in DVM and current shunt measure the actual power supply output and provide you with 16-bit readback. The programming command set is easy-to-use and includes software calibration commands. The interface card comes standard with several protection features such as programmable over voltage protection, foldback, load isolation signal, and soft limits.

Figure 1.1 Sample Configuration using GPIB Interface (1200 Watt DC Power Supplies Shown)

Release 3.1

11

Image 13
Contents GPIB-XHR GPIB-XFR GPIB-XFR3 Page Operating Manual for Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Model Number Serial Number Purchased From Purchase Date Information About Your Power SupplySupply SafetyManual Revisions Main SectionsAbout This Manual Contents Contents Description Features and SpecificationsFeatures and Specifications Features and FunctionsFunctions ReadbackModels 140 12-100 20-60 35-35 40-30 SpecificationsOVP Models 60-20 100-12 150-8 300-4 600-2 Models 300 12-220 20-130 33-85 40-70 Models 60-46 100-28 150-18 300-9 600-4 Models 130 20-50 33-33 40-25 60-18 Models 100-10 150-7 300-3.5 600-1.7 Initial Inspection IntroductionInitial Inspection Installation and ConfigurationGpib Interface Subplate Located on Power Supply Rear Panel Gpib Interface PCB Step # Description Action Reference Basic Setup ProcedurePON SRQ Address IEEE-488 Primary Address SelectionRear Panel SRQ Switch Position PON SRQ State Power On Service Request PON SRQSwitch Position Power on results Iset Condition Default Settings Model ExampleIbfind devname Internal PCB Jumper Selections IEEE-488 Controller ConnectionHigh LOW OFF High OFF LOWUser Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Gpib Operation OperationExample Ascii Request Service SRQ Set when Bit Decimal Description Reset By Position WeightPower On PON Set when unit LSBComputer Entry Command SyntaxFormat Floating Number Definition Example Description FormIset 2.0A Vset Command Summary AUXB? AUXA?CMODE? DLY?Cmode FAULT?Idata IHICommand Description Command ReferenceAuxa 1 on Auxb 1 onChanging an output setting Response Fold mode where mode is Mask None = Unmask ALL SnspStatus, and Fault Registers on SNSP, ALL, None Accumulated Status, Status, and Fault Registers onResponse Vmax voltage Condition Mnemonic Bit Position Bit Weight Accumulated Status, Status, and Fault Registers11 Error Codes Error CodesLEDs TroubleshootingCalibration Setup Voltage Mode CalibrationVoltage Program Calibration Procedure Readback VoltageCalibration Current Calibration Setup Current Mode CalibrationCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc