Xantrex Technology Frame Optional PV Conductor PV Array Ground Jumper, PV-30208 Inverter

Page 13

SECTION 3

INSTALLATION AND INITIAL TURN-ON

Ground

Frame

Optional PV Conductor

 

 

 

 

PV Array

 

Ground Jumper

+

-

 

PV+

PV-

 

 

 

PV-30208

Inverter

 

GND

 

 

 

 

 

DNG

 

Wiring Diagram (Optional)

Box

Xantrex Combiner

X1X2H0H1

NC (Optional)

TransformerIsolation

H3

 

 

X3

 

 

X0

 

 

H2

 

 

C

B

A

Distribution System Ground

Breaker To Single Point Electrical

Line Circuit

DOCUMENT: 151315PV-30208 Photovoltaic Inverter3-6

Operation and Maintenance Manual

Copyright 2003, Xantrex Technology Inc.

Image 13
Contents Copyright 2003, Xantrex Technology Inc South Vasco RoadTable of Contents Major Components Section Product Description IntroductionMain Enclosure Interconnection Standards Compliance Section Product DescriptionMatrix Bus Board Solar Control Unit SCUEquipment Symbol Section Product Description SpecificationsEnclosure Front Access Panel Section Safety Safety FeaturesPV Ground Fault Detection Anti Island Protection Section Safety Isolation ProcedureUtility Side Isolation Transformer Requirements Torque and Wire Gauge SpecificationsInstallation Instructions Section Installation and Initial TURN-ONInstallation Floor MountedSection Installation and Initial TURN-ON Phase-Sequencing Ground Fault DetectionArray Grounding Section Installation and Initial TURN-ON Frame Optional PV Conductor PV Array Ground Jumper Wiring Diagram Optional BoxPV-30208 Inverter Initial Power Visual Inspection, PV Array WiringVisual Inspection, Isolation Transformer WYE/WYE Visual Inspection, PV-30208System Verification Fine TuningOverview Section Operation Description of System OperationOperating States Section Operation Operation Features Section Operation Diagram Of Monopolar ConfigurationBlock Current Imbalance Detection Peak Power TrackingDC Overvoltage Detection Automatic Wake Up PV Voltage OptimizationSection Operation Operator Interface Example of Normal System Operation System Fault System Sleep Test System Stop System ShutdownSection Operation System Operating Parameters User Factory Password Parameter Description Section Operation Fault Conditions Section Troubleshooting GeneralIPM Device Fault 0x0001 Through Fault DescriptionsAC Line Voltage Low Fault Section TroubleshootingAC Line Voltage High Fault AC Line Under Frequency FaultGround Current Fault AC Line Over Frequency FaultDC Bus Over Voltage Fault CT Offset FaultStop Switch Fault Current Imbalance FaultSection Preventative Maintenance Periodic Maintenance TURN-ON Procedure Section Preventative MaintenanceWarranty and Certifications Section Drawings and Parts List Drawings ListOptional Accessories Page Page Page Page Page Enclosure, Upper Page Xantrex PV Series Limited Warranty and Registration