Xantrex Technology PV-30208 important safety instructions Enclosure, Upper

Page 38

Xantrex Technology Inc. PV-30208

Photovoltaic Inverter

Major Parts List

Assembly Description: Main Enclosure, Control Components, PV-30208

Xantrex Technology Inc. Assembly # 151317

Item #

Qty

Reference Designator

Xantrex Technology Part #

Description

1

1

-

1-160070-01

Enclosure, Upper

2

1

-

1-160051-01

Enclosure, Lower

3

1

-

1-160071-01

Assy, Heatsink, PV-30208

4

1

T1

1-160015-01

Transformer, 175VA, 24V

5

1

LF1

1-150684-01

Filter, EMI, 115/250 VAC, 2 Amp

6

1

K1

1-150668-80

Contactor, 3P, 24VDC Coil, 80A

7

2

TB1-2

1-160012-01

Block, Power Distribution, Inter, 3P

8

2

B1,B2

1-150714-01

Fan, 24VDC, 6", 240CFM, 53.3dB

9

1

L1

1-150862-01

Reactor, Line, 3 Ph, 158uH, 98 ARMS

10

3

C1-3

1-150403-02

Capacitor, NP, 4uF, 600VAC, 6%

11

3

L2-4

1-160008-01

Reactor, PWM, 1 Ph, 450uH, 83 ARMS

12

1

-

1-150378-02

Assy, PCB, DSP

13

1

PS1

1-160044-01

Assy,PCB, 24VDC, 100W

14

1

PS2

1-160006-01

Power Supply, Single Out, +15VDC

15

1

PS3

1-160030-01

Power Supply, Triple Out, +5, +/-15VDC

16

1

-

1-160052-01

Assy, Panel, Display

17

1

-

1-160049-01

Assy, Bus, 600V, 100A

18

3

F1-F3

1-151719-02

Fuse, 250V, 125A

19

3

-

1-151720-01

Fuse Holder, Semi-Conductor Fuse

20

1

-

1-151565-02

Assy, PCB, SCU-UL, WDM, Tested, 30kW

21

2

CT1,CT5

1-150296-01

CT, Hall Effect, 200A:1mA

22

1

T2

1-151843-01

Transformer, Iso, 230/115:230/115, 200VA

23

2

-

1-160094-01

Fuse Holder, 30A, 600V, 2Pole

24

4

F4-F7

1-160092-01

Fuse, Time Delay, 250VAC

25

3

-

1-151241-01

Terminal Block, 1Pole, 24-8 AWG

26

1

-

1-151242-01

Barrier Block, 24-18 AWG

151317

Sheet 2 of 2

Image 38
Contents South Vasco Road Copyright 2003, Xantrex Technology IncTable of Contents Main Enclosure Section Product Description IntroductionMajor Components Matrix Bus Board Section Product DescriptionInterconnection Standards Compliance Solar Control Unit SCUSection Product Description Specifications Equipment SymbolPV Ground Fault Detection Section Safety Safety FeaturesEnclosure Front Access Panel Section Safety Isolation Procedure Anti Island ProtectionTorque and Wire Gauge Specifications Utility Side Isolation Transformer RequirementsInstallation Section Installation and Initial TURN-ONInstallation Instructions Floor MountedSection Installation and Initial TURN-ON Array Grounding Ground Fault DetectionPhase-Sequencing Section Installation and Initial TURN-ON PV-30208 Inverter Wiring Diagram Optional BoxFrame Optional PV Conductor PV Array Ground Jumper Visual Inspection, Isolation Transformer WYE/WYE Visual Inspection, PV Array WiringInitial Power Visual Inspection, PV-30208Fine Tuning System VerificationOperating States Section Operation Description of System OperationOverview Section Operation Operation Features Block Diagram Of Monopolar ConfigurationSection Operation DC Overvoltage Detection Peak Power TrackingCurrent Imbalance Detection Automatic Wake Up PV Voltage OptimizationSection Operation Operator Interface System Fault System Sleep Test System Stop System Shutdown Example of Normal System OperationSection Operation System Operating Parameters User Factory Password Parameter Description Section Operation Section Troubleshooting General Fault ConditionsFault Descriptions IPM Device Fault 0x0001 ThroughAC Line Voltage High Fault Section TroubleshootingAC Line Voltage Low Fault AC Line Under Frequency FaultDC Bus Over Voltage Fault AC Line Over Frequency FaultGround Current Fault CT Offset FaultCurrent Imbalance Fault Stop Switch FaultSection Preventative Maintenance Periodic Maintenance Section Preventative Maintenance TURN-ON ProcedureOptional Accessories Section Drawings and Parts List Drawings ListWarranty and Certifications Page Page Page Page Page Enclosure, Upper Page Xantrex PV Series Limited Warranty and Registration