Multiquip MQP20P manual Generator Storage, Adjustment Procedure

Page 35

maintenance

used to adjust the generator output voltage. Clockwise adjustment increases the generator output voltage.

2.Stability Adjust System stability is the ability of the generator to respond to load transients. Decreasing the stability makes the generator less sluggish and faster to respond to load transients.

If the stability of the regulator is decreased too much, the generator will tend to hunt under steady state conditions. Increasing stability increases the response time of the generator while decreasing stability decreases response time.

The screwdriver adjustable potentiometer is used to adjust the system stability. Clockwise adjustment increases stability.

3.Roll-Off Frequency Selection The roll-off point is the frequency where the generator voltage starts to decrease.This reduces the kilowatt load to the engine, which allows the engine to recover in speed under any load transient condition.

The voltage regulator has the roll-off point preset to 58 Hz in the 60 Hz mode. To change the roll off point, perform the following:

a.Adjust the engine to the desired rated speed (60 Hz).

b.Set the voltage to the desired setting at rated speed.

c.Adjust the engine speed to the desired roll-off point.

d.Turn the potentiometer counterclockwise until the voltage returns to rated.

e.Readjust the engine speed to rated speed.

F1 and the negative lead to F2 or use an appropriate AC voltmeter on the generator output leads.

6.Start and run the generator at no load and rated speed. The generator voltage should build up to a minimum level. If it does not build up, refer to the generator manual for field flashing information.

7.Slowly adjust the Voltage Adjust potentiometer until the generator voltage reaches the nominal value. Also adjust the remote Voltage adjust to set the generator voltage to the exact value desired.

8.Turn the Stability Adjust potentiometer counterclockwise until instability is shown on the voltmeter. With the system operating in an unstable condition, slowly adjust the Stability Adjust potentiometer clockwise until generator stability is reached.

9.Interrupt the regulator power for a short period of time (1 to 2 seconds).

10.If the generator remains stable, no further adjustment is necessary.

11.If generator does not remain stable, increase the stability slightly and interrupt the regular power again.

12.Repeat step 11 until system stability is reached and maintained.

Generator Storage

For long term storage of the generator the following is recommended:

1.Drain the fuel tank completely.Treat with a fuel stabilizer if necessary.

2.Completely drain the oil from the crankcase and refill, if necessary, with fresh oil.

Adjustment Procedure

1.Make sure that the voltage regulator is connected correctly to the generator. Refer to the generator wiring diagram.

2.Turn the Voltage Adjust potentiometer fully counterclockwise.

3.Turn Stability Adjust potentiometer fully clockwise.

4.Set the remote Voltage Adjust to the center position.

5.Connect the positive lead of a 100 VDC voltmeter to

3.Clean the entire generator, inside and outside.

4.Disconnect the battery.

5.Make sure engine coolant is at proper level.

6.Cover the generator and store in a clean, and dry place.

MQP20P STANDBY GENERATOR • operation and parts manual — rev. #1 (11/28/11) — page 35

Image 35
Contents Model MQP20P Diesel engine exhaust and some Proposition 65 warningPage MQP20P Standby Generator Table of ContentsChoose from three easy options SaFeTY MeSSageS Safety InformationGeNeRaTOR SaFeTY GeNeRal SaFeTYRestricted. If the air fl ow is ENgiNe SaFeTYTOWiNg SaFeTY Fuel SaFeTYPower Cord/Cable Safety EleCTRiCal SaFeTYGrounding Safety ENviRONMeNTal SaFeTY BaTTeRY SaFeTYSpecifications Dimensions Typical Generator Grounding Application InstallationGenerator Grounding Outdoor InstallationIndoor Installation MountingCamlok outlet box panel General informationGenerator ElectrONIC Governor System Principle of operationEngine Item no Description Major componentsBasic Engine Components Basic engine componentsMicroprocessor Engine Controller MEC Digital controller panelOutlet connectors Connector outlet box and main circuit breakerGenerator Amperage Single Phase LoadLoad application/generator output Fuel Check Inspection/setupRefueling Procedure Lubrication OilFuel Expands Coolant Antifreeze/summer coolant Cleaning the RadiatorAir Cleaner Fan Belt Tension BatteryPiping and Hose Connection Battery Cable InstallationWiring AlternatorStarting Manual Starting Auto ModeStartup Before StartingEmergency Shutdown Procedure Normal Shutdown ProcedureBattery Charger and Jacket Water Heater Power Connections JacketWater Heater and Internal Battery ChargerProtective devices Protective devicesTransporting TransportingGeneral Inspection Air Filter MaintenanceAir Filter Dust Indicator Fuel Tank Inspection Cleaning Inside the Fuel TankFuel Addition Removing Water from the Fuel TankPotentiometers Radiator CleaningVoltage regulator adjustments Flushing Out Radiator and Replacing CoolantGenerator Storage Adjustment ProcedureTroubleshooting Generator Troubleshooting GeneratorTroubleshooting Engine Troubleshooting engineTroubleshooting MEC20 Controller Troubleshooting controllerImproper calibration? Troubleshooting Voltage Regulator Troubleshooting Voltage RegulatorMaintenance Parts Locator Control BOX Generator Wiring Diagram single phaseCircuit Breaker BOX Generator Wiring Diagram three phase 505 K1 Explanation of Code in Remarks Column MQP20P with Perkins 404D-22 Diesel Engine 1 to 3 units Suggested Spare PartsHousing assy Part Name Engine and Generator Mounting assy GENERATOR, 30KW Fuel assy Part Name QTY Remarks Electrical assy BOLT, BATTERY, 10.38 Jacket Water HEater assy BRACKET, MOUNTING, Heater Solenoid assy BRACKET, Starter Solenoid Radiator assy Guard Air filter assy Cover Engine exhaust assy Exhaust Flex Engine Oil assy OIL Filler CAP Control panel assy PANEL, FRONT, Control Panel Controller assy MODULE, Output Expan MEC 2/20 W/CABLE Saddlebox assy Phase Units Circuit breaker assy Ground Camlok assy HousingCOVER, HINGED, Black FReigHT pOliCY Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help