PROBLEM | PROBABLE CAUSE | SOLUTION |
| |
| No fuel. | Add fuel (page 22). |
| |
| Stale fuel. | Drain fuel tank; fill with fresh fuel (page 26). | ||
| No or low engine oil. | Add engine oil (page 22). |
| |
Engine will not start or | Spark plug wire (cap) disconnected. | Install spark plug cap over spark plug. |
| |
starts and runs rough | Faulty/bad spark plug. | Check/replace spark plug (see Honda Owner’s Manual). | ||
| Fuel not reaching carburetor. | Clean fuel sediment cup (page 24). |
| |
| Dirty air filter. | Clean or replace air filter (see Honda Owner’s Manual). | ||
| Dirty spark arrestor screen. | Clean spark arrestor screen (page 23). |
| |
Engine suddenly stops | No fuel. | Add fuel (page 22). |
| |
No or low engine oil. | Add engine oil (page 22). |
| ||
|
| |||
| Electrical overload on generator. | Check all circuit breakers for “tripped’ |
| |
| position or overload indicator light on. |
| ||
|
|
| ||
|
| Reduce electrical load on circuit, wait |
| |
|
| several minutes for thermal breakers to |
| |
No power at AC |
| cool (master breaker is not thermal), | Set Tripped | |
| and then push to reset circuit breaker. |
| ||
receptacle |
|
| ||
Poor connection or defective cord. | Check cord connection. Replace defective cord. | |||
| ||||
| Connected electrical appliance/ | Check electrical appliance/equipment for defects. Dis- | ||
| connect defective appliance/equipment from the genera- | |||
| equipment is defective. | |||
| tor. Have appliance serviced by qualified repair facility. | |||
|
| |||
Speed of starter motor | Battery is losing charge. | Recharge battery. |
| |
drops after period of time |
| |||
|
|
| ||
TABLE 5. Troubleshooting — Probable Causes and Solutions |
|
|