Section 1 — General Information

Air-cooled Generators

Figure 1.5 - 10kW, GT-530 (Inlet Hose Slid Back)

Fuel Selection

Lever - "In"

Position for

Natural Gas

Fuel

Figure 1.6 - 10kW, GT-530 (Inlet Hose Slid Back)

Fuel Selection

Lever - "Out"

Position for

Liquid Propane

(Vapor) Fuel

Figure 1.7 - 13/16kW, GT-990 (Airbox Cover

Removed)

Fuel Selection Lever - "In" Position for Natural Gas Fuel

Figure 1.8 - 13/16kW, GT-990 (Airbox Cover

Removed)

Fuel Selection Lever - "Out" Position for Liquid Propane

(Vapor) Fuel

1.10 LOCATION

‹1.10.1 GENERATOR

Install the generator set, in its protective enclosure, outdoors, where adequate cooling and ventilating air is always available (Figure 1.9). Consider these fac- tors:

The installation of the generator must comply strictly with NFPA 37, NFPA 54, NFPA 58, and NFPA 70 standards.

Install the unit where air inlet and outlet open- ings will not become obstructed by leaves, grass, snow, etc.. If prevailing winds will cause blowing or drifting, consider using a windbreak to protect the unit.

Install the generator on high ground where water levels will not rise and endanger it.

Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed in accordance with current applicable NFPA 37 and NFPA 70 standards; as well as any other federal, state and local codes for minimum distances from other structures. DO NOT install under wooden decks or structures.

Install the unit where rain gutter down spouts, roof fun-off, landscape irrigation, water sprinklers or sump pump discharge does not flood the unit or spray the enclosure, including any air inlet or outlet openings.

Install the unit where services will not be affected or obstructed, including concealed, underground or covered services such as electrical, fuel, phone, air conditioning or irrigation.

Where strong prevailing winds blow from one direction, face the generator air inlet openings to the prevailing winds.

9

Image 11
Contents Listed Authorized Dealer Location IntroductionIntroduction Inside Front Cover Post Installation Start-up AdjustmentsMaintenance Troubleshooting Warning  ‹ Standards Index  Electrical Hazards Breaker for Bedrooms UNPACKING/INSPECTIONProtection Systems 7kW, Single Cylinder GH-410 Engine Generator‹ 1.5.2 Engine Specifications‹ 1.5.1 Generator ‹ 1.8.1 BTU Flow Requirements Natural GAS System SET LEDFuel Requirements Recommendations Fuel Consumption‹ 1.9.2 10, 13 and 16KW, V-TWIN Engines Reconfiguring the Fuel System‹ 1.9.1 7 KW, 410CC Engine ‹ 1.10.1 Generator Location10.2.1 7, 10, 13, and 16 kW Units if equipped Battery RequirementsBattery Installation ‹ 1.10.2 Transfer Switch10 Battery Cable Connections BatteryElectrical Checks Check Transfer Switch OperationBefore Initial START-UP 7KW Natural GAS only Generator Tests Under LoadChecking Automatic Operation ‹ 2.7.1 7 KW Units Engine Governor Adjustment‹ 3.1.3 Manual Position ‹ 3.1.1 Auto Position‹ 3.1.4 Choke Operation Automatic Transfer OperationSequence of Automatic Operation Manual Transfer Operation‹ 3.4.2 Transfer Back to Utility Power Source Setting the Exercise TimerApproximate Crank Cycle Times ‹ 3.6.1 LOW OIL Pressure Switch‹ 3.6.2 High Temperature Switch ‹ 3.6.3 Overcrank‹ 3.6.5 RPM Sensor Failure ‹ 3.6.6 LOW BatteryChecking the Engine OIL Level Fuses‹ 4.3.2 Engine OIL Recommendations Changing the Engine OIL‹ 4.3.1 OIL Change Intervals ‹ 4.4.2 10KW Generators Spark Plugs‹ 4.4.1 7, 13, and 16KW Generators Valve Clearance Battery Maintenance11 Cooling Vent Locations Cooling SystemCorrosion Protection OUT of Service Procedure‹ 4.11.2 Return to Service ‹ 4.11.1 Removal from ServiceBe performed by the nearest Authorized Dealer Service ScheduleProblem Cause Correction Troubleshooting GuideAir-cooled Generators Air-cooled Generators Air-cooled Generators Mounting Dimensions Electrical Data Engine Wiring Customer Connection Battery Charger Engine Alternator Engine Wiring Stator Electronic Voltage Regulator Manual Auto Scsm Neutral Electrical Data Electrical Data Sheet Metal PAINT/MATERIAL Code Legend Part NO. QTY. Description Air-cooled Generators Control Panel Drawing No F9695-C QTY Description Exploded Views and Parts Lists BOX Load Center Exploded Views and Parts Lists Description QTY Exploded Views and Parts Lists Washer Flat M8 5/16 Exploded Views and Parts Lists Crankcase Exploded Views and Parts Lists Intake Adapter Exploded Views and Parts Lists PIN, Piston D20 Exploded Views and Parts Lists SCREW, Taptite M6-1.0X8 Yellow Chrome Air-cooled Generators 7kW, GN-410 Engine Drawing No F9422-B ADAPTOR, Engine Exploded Views and Parts Lists ADATOR, Engine 7KW CASTING, Twin Regulator Housing 7KW Exploded Views and Parts Lists Brkt Regulator Mounting PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power Systems Standard Limited Warranty for