Casablanca Fan Company C31UxxZ w-84 Control INSTALLATION Installing the W-84 Wall Control

Page 26
w-84 Control INSTALLATION

®3

w-84 Control INSTALLATION

Installing the W-84 Wall Control

NOTE: W-84 Wall Control should only be installed on Casablanca's Inteli-Touch®3 fans with UPLIGHTS ONLY or both an UPLIGHT and a DOWNLIGHT on the fan.

The wall control installs in the same manner as an ordinary light switch, using an existing wall box and wiring. This controller is designed to signal the fan microcomputer as well as perform normal switching operations. For this reason the following precautions must be observed:

1.Use only the Casablanca W-84 wall control.

2.Do not use any additional control with your Inteli- Touch 3 fan (for example, dimmer, or fan speed control).

3.Do not use more than one fan per wall control.

4.No other light fixtures or electrical appliances may be connected on the circuit controlled by the W-84 wall control.

single W-84 Installation

CAUTION!

Ensure power is turned OFF at the breaker or fuse panel before starting installation.

W-84 is used to describe either white (-11) or almond finish. If you have multiple Inteli-Touch®3 fans, refer to the section "Changing Frequency Setting" on page 6.

1.Remove the screws and switch plate from the existing switch box.

2.Remove the screws holding the switch in the switch box.

3.Pull the existing switch from the switch box to expose the wire connections.

4.Remove the two wires from the switch.

5.Connect the BLACK wire from the POWER SOURCE that you just removed from the switch to the BLACK/ WHITE STRIP wire on the W-84 wall control. Secure this connection with a wire nut.

6.Connect the second BLACK wire that you just removed from the switch to the second BLACK wire on the located on the back of the W-84 wall control. Secure this connection with a wire nut.

7.Connect the green ground wire coming from the back of the W-84 control to the ground wire in the switch box. Secure the splice with a wire nut.

NOTE: The RED wire is not used in this application. DO NOT remove the crimped cap from the wire.

8.Check your work by using the wiring diagrams as shown in Figures # 1 and #2.

9.Install the W-84 in the wall box with the

two long screws provided.

10.Install the wall plate with the two color- matched screws.

(FIGURE #1)

2BLACK

WIRES

W-84

Wall Control

RED WIRE

NOT USED

 

BLACK AND WHITE

(FIGURE #2)

STRIPED WIRE

 

24

Image 26
Contents C31UxxZ PN C3143001-AT0209Holliston O W N E R ’ S M A N U A LTHIS WARRANTY SUPERSEDES ALL HollistonPREVIOUS WARRANTIES Proof of PurchaseLIMITED WARRANTY Read and Save These Instructions CONTENTSHolliston PN C3143001 AT0608Holliston SERIAL No. DJ06MODEL # C31UxxZ TYPEUplight Bulbs Parts Guide7-Watt Incandescent Switch Housing Cap Blade Iron Screws pre-installed, see pg 13, step 9aAdaptor Assembly Switch Housing Cap Screws 8-32 x 3/8Introduction Before You Start For best performance and for your warranty to be validuse only genuine Casablanca blades, light fixtures, and accessories Safe UseMOUNTING RECOMMENDATIONS General Guidelines sloped ceiling installationsWhen to Use Extension Poles Calculation of Ceiling AngleInstalling a New Ceiling Fixture Outlet Box Fan Installation Getting StartedCeiling plate Installation Using Existing Ceiling Fixture Outlet BoxCANOPY LOCK WASHERS CANOPY SCREWS Lag Screw InstallationCanopy Installation Fan Preparation IMPORTANT SAFETY INFORMATIONPrepare for fan installation as follows Figure #1 Figure #2Figure #5 Fan Preparation - continuedFigure #4 Hanging the Fan LIGHTBULB INSTALLATION uplightInstall Lightbulbs Figure #6Figure #2 Canopy Hatch and cover ring InstallationCanopy Electrical Connections Attach Blade Irons Blade InstallationBlade Installation Blade screws must be tightened securely LIGHT FIXTURE Installation optionalBlade Installation Continued before operating the fanLight Kit Adaptor Disassembly switch housing and end cap InstallationNO LIGHT KIT - Installation Switch Housing and Light Kit Adaptor Installation - NO LIGHT KIT Adaptor Installation NO LIGHT KIT - END Switch Housing and Light KitAdaptor Installation - Continued NO LIGHT KIT SCREW Figure #6LIGHT KIT - Installation Figure #9 Switch Housing and Light KitAdaptor Installation - Continued LIGHT KIT Figure #12 Figure #10Figure #11 Figure #14Figure #17 Figure #15Figure #16 W-84 Wall control Preparation W-84 WALL CONTROL INSTALLATIONPrepare for W-84 Wall Control Bezel replacement as follows For use on product with BOTH UP and DOWN LIGHTS ONLYRUBBER KEY PAD Prepare for W-84 Wall Control installation - ContinuedPINS ALMONDW-84 Wall Control w-84 Control INSTALLATION Installing the W-84 Wall Controlsingle W-84 Installation NEUTRAL dual W-84 InstallationDIP SWITCHES Operation Speed Control Operation PowerMake sure where you are in the sequence to the right Operation Reversing AirflowTo dim just the down light changing frequency settingTo dim just the up light NOTE All fans leave the factory set to “1111”Operation Safe-Exit and light-minder Program Automatic Demonstration Program++++ To enter the demonstration program+ + + Operation Home-Safe ProgramOperation Fan-Minder Program In the wall bezel replacement W-84 Wall Control Bezel replacement CONTINUED ALMOND WALL PLATE SCREWS ALMOND COLORED WALL PLATE BEZEL BEZEL TABS BEZEL ALIGNMENT PIN AND HOLEALMOND COLORED BEZEL Troubleshooting tips Weight Product SpecificationsDimensions Care RecommendationsHolliston