Canopy Electrical Connections

Step 7. Attach the fan wires to the ceiling fixture outlet box wiring by placing the bare ends of the wires side by side and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut. Connect in this order:

GREEN leads from mounting plate and downrod assembly of fan to GROUND conductor of power source. Secure with wire nut.

WHITE wire from fan to white NEUTRAL wire in ceiling fixture outlet box. Secure with wire nut.

BLACK power wire from fan to BLACK power wire in ceiling outlet box. Secure with wire nut.

NOTE: If the color of your ceiling wires differs from that described, consult an electrician.

WIRE NUT

2 BLACK WIRES

2 WHITE WIRES

3 GREEN WIRES

Canopy Hatch and cover ring Installation

Step 8a. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening.

Step 8b. Install the canopy hatch with the last canopy screw and lock washer using the provided screwdriver. To do this, tilt the fan body away from the hatch opening. Tighten the screws firmly.

Step 8c. Straighten the fan, then check to ensure there is no movement between the canopy and the ceiling or the Perma•Lockdownrod and the ball assembly.

Step 8d. Locate the locking pins on the canopy cover ring as shown in Figure #2. Lift up on the canopy cover ring and guide the two (2) locking pins into the two (2) locking holes, then snap the canopy cover in to place as shown in Figure #3.

CANOPYCanopy Hatch and cover ring Installation

HATCH

CANOPY

SCREW &

WASHER

Figure #1

Figure #2 CANOPY

CANOPY

COVER

RING

LOCKING

HOLES

LOCKING PINS

Figure #2

Figure #3

12

Image 14
Contents C31UxxZ PN C3143001-AT0209Holliston O W N E R ’ S M A N U A LTHIS WARRANTY SUPERSEDES ALL HollistonPREVIOUS WARRANTIES Proof of PurchaseLIMITED WARRANTY Read and Save These Instructions CONTENTSHolliston PN C3143001 AT0608Holliston SERIAL No. DJ06MODEL # C31UxxZ TYPEUplight Bulbs Parts Guide7-Watt Incandescent Switch Housing Cap Blade Iron Screws pre-installed, see pg 13, step 9aAdaptor Assembly Switch Housing Cap Screws 8-32 x 3/8Introduction Before You Start For best performance and for your warranty to be validuse only genuine Casablanca blades, light fixtures, and accessories Safe UseMOUNTING RECOMMENDATIONS General Guidelines sloped ceiling installationsWhen to Use Extension Poles Calculation of Ceiling AngleInstalling a New Ceiling Fixture Outlet Box Fan Installation Getting StartedCeiling plate Installation Using Existing Ceiling Fixture Outlet BoxCANOPY LOCK WASHERS CANOPY SCREWS Lag Screw InstallationCanopy Installation Fan Preparation IMPORTANT SAFETY INFORMATIONPrepare for fan installation as follows Figure #1 Figure #2Figure #5 Fan Preparation - continuedFigure #4 Hanging the Fan LIGHTBULB INSTALLATION uplightInstall Lightbulbs Figure #6Figure #2 Canopy Hatch and cover ring InstallationCanopy Electrical Connections Attach Blade Irons Blade InstallationBlade Installation Blade screws must be tightened securely LIGHT FIXTURE Installation optionalBlade Installation Continued before operating the fanLight Kit Adaptor Disassembly switch housing and end cap InstallationNO LIGHT KIT - Installation Switch Housing and Light Kit Adaptor Installation - NO LIGHT KIT Adaptor Installation NO LIGHT KIT - END Switch Housing and Light KitAdaptor Installation - Continued NO LIGHT KIT SCREW Figure #6LIGHT KIT - Installation Figure #9 Switch Housing and Light KitAdaptor Installation - Continued LIGHT KIT Figure #12 Figure #10Figure #11 Figure #14Figure #17 Figure #15Figure #16 W-84 Wall control Preparation W-84 WALL CONTROL INSTALLATIONPrepare for W-84 Wall Control Bezel replacement as follows For use on product with BOTH UP and DOWN LIGHTS ONLYRUBBER KEY PAD Prepare for W-84 Wall Control installation - ContinuedPINS ALMONDW-84 Wall Control w-84 Control INSTALLATION Installing the W-84 Wall Controlsingle W-84 Installation NEUTRAL dual W-84 InstallationDIP SWITCHES Operation Speed Control Operation PowerMake sure where you are in the sequence to the right Operation Reversing AirflowTo dim just the down light changing frequency settingTo dim just the up light NOTE All fans leave the factory set to “1111”Operation Safe-Exit and light-minder Program Automatic Demonstration Program++++ To enter the demonstration program+ + + Operation Home-Safe ProgramOperation Fan-Minder Program In the wall bezel replacement W-84 Wall Control Bezel replacement CONTINUED ALMOND WALL PLATE SCREWS ALMOND COLORED WALL PLATE BEZEL BEZEL TABS BEZEL ALIGNMENT PIN AND HOLEALMOND COLORED BEZEL Troubleshooting tips Weight Product SpecificationsDimensions Care RecommendationsHolliston