Step 12a. Locate and remove the three #8-32 screws from the center shaft adapter located on the bottom of the fan as shown in Figure #1. Do not discard the screws, all three screws will be needed for the next steps with in this document.

Step 12b. Locate the light kit adaptor plate and thread the BLUE and WHITE wires through the hole in the center of the light kit adaptor plate, also as shown in Figure #2.

Step 12c. Locate the three screws that you removed from the center shaft adapter during Step 12a. These three screws are needed to attached the light kit adaptor plate to the fan. Align the screw hole on the light kit adaptor plate with the screw holes on the center shaft adaptor and insert all three screws as shown in Figure #3. Then tighten all three screws with the provided screwdriver.

CENTER SHAFT

ADAPTER

ADAPTER SCREWSManual background , #8-32

Figure #1

LIGHT KIT

ADAPTOR

PLATE

WHITE

WIREBLUE WIRE

Figure #2

CENTER SHAFT

ADAPTER

LIGHT KIT

ADAPTOR

PLATE Manual background

SCREWS , #8-32 Manual background

Figure #3

NOTE: Make sure that the wire nuts on the ends of the WHITE and BLUE wires are securely attached to the ends of the wires and that the wires are tucked out of the way so that the wires are not pinched when attaching the cap.

Step 12d. Locate the light kit adaptor plate cap as shown in Figure #4 and align the four screw holes on the cap with the holes on the light kit adaptor plate. Using the four (4) screws that you removed earlier from the light kit adaptor assembly (see step 11c), insert the four screws, attaching the cap to the bottom of the fan. Then tighten all four screws with the provided screwdriver.

WIRE NUTS

 

(WHITE and BLUE)

LIGHT KIT

WIRES

ADAPTOR

 

CAP

PLATE

 

SCREWS, #6-32 Manual background

Figure #4

16

Image 18
Contents C31UxxZ PN C3143001-AT0209Holliston O W N E R ’ S M A N U A LProof of Purchase LIMITED WARRANTYTHIS WARRANTY SUPERSEDES ALL HollistonPREVIOUS WARRANTIES Read and Save These Instructions CONTENTSHolliston PN C3143001 AT0608Holliston SERIAL No. DJ06MODEL # C31UxxZ TYPEParts Guide 7-Watt IncandescentUplight Bulbs Switch Housing Cap Blade Iron Screws pre-installed, see pg 13, step 9aAdaptor Assembly Switch Housing Cap Screws 8-32 x 3/8Introduction Before You Start For best performance and for your warranty to be validuse only genuine Casablanca blades, light fixtures, and accessories Safe UseMOUNTING RECOMMENDATIONS General Guidelines sloped ceiling installationsWhen to Use Extension Poles Calculation of Ceiling AngleInstalling a New Ceiling Fixture Outlet Box Fan Installation Getting StartedCeiling plate Installation Using Existing Ceiling Fixture Outlet BoxLag Screw Installation Canopy InstallationCANOPY LOCK WASHERS CANOPY SCREWS Fan Preparation IMPORTANT SAFETY INFORMATIONPrepare for fan installation as follows Figure #1 Figure #2Fan Preparation - continued Figure #4Figure #5 Hanging the Fan LIGHTBULB INSTALLATION uplightInstall Lightbulbs Figure #6Canopy Hatch and cover ring Installation Canopy Electrical ConnectionsFigure #2 Blade Installation Blade InstallationAttach Blade Irons Blade screws must be tightened securely LIGHT FIXTURE Installation optionalBlade Installation Continued before operating the fanswitch housing and end cap Installation NO LIGHT KIT - InstallationLight Kit Adaptor Disassembly Switch Housing and Light Kit Adaptor Installation - NO LIGHT KIT Adaptor Installation NO LIGHT KIT - END Switch Housing and Light KitAdaptor Installation - Continued NO LIGHT KIT SCREW Figure #6LIGHT KIT - Installation Switch Housing and Light Kit Adaptor Installation - Continued LIGHT KITFigure #9 Figure #12 Figure #10Figure #11 Figure #14Figure #15 Figure #16Figure #17 W-84 Wall control Preparation W-84 WALL CONTROL INSTALLATIONPrepare for W-84 Wall Control Bezel replacement as follows For use on product with BOTH UP and DOWN LIGHTS ONLYRUBBER KEY PAD Prepare for W-84 Wall Control installation - ContinuedPINS ALMONDw-84 Control INSTALLATION Installing the W-84 Wall Control single W-84 InstallationW-84 Wall Control dual W-84 Installation DIP SWITCHESNEUTRAL Operation Speed Control Operation PowerMake sure where you are in the sequence to the right Operation Reversing AirflowTo dim just the down light changing frequency settingTo dim just the up light NOTE All fans leave the factory set to “1111”Operation Safe-Exit and light-minder Program Automatic Demonstration Program++++ To enter the demonstration programOperation Home-Safe Program Operation Fan-Minder Program+ + + In the wall bezel replacement W-84 Wall Control Bezel replacement CONTINUED BEZEL BEZEL TABS BEZEL ALIGNMENT PIN AND HOLE ALMOND COLORED BEZELALMOND WALL PLATE SCREWS ALMOND COLORED WALL PLATE Troubleshooting tips Weight Product SpecificationsDimensions Care RecommendationsHolliston