Troubleshooting Tips 7-13

Close Adapter Test Failure

Make sure a lobe cable is properly connected to the adapter
and that the other end of the cable is connected to a DAU,
MAU, or CAU.
Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.

Adapter Wrap Test Failure (Group 2)

Make sure a lobe cable is properly connected to the adapter.
For an adapter with UTP cabling, the other end of the cable
needs to be connected to a MAU.
Try another shared RAM address and size.
Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.
Troubleshooting Tips
If the diagnostic tests fail, the adapter may not be defective.
The problem may be incorrect option settings or option
settings that conflict with the settings of other boards, or
the adapter may be improperly installed. Follow these steps
to test the adapter further.
CAUTION: Make sure that you turn off the power before
inserting or removing the adapter from the PC.
1Make sure that the 3C619C adapter is installed in a UL-listed
PC containing an ISA or EISA bus.
2Make sure that the board is seated firmly and all the way
down in the slot. Check the adapter installation by
reviewing the installation instructions in Chapter 2.
3Inspect all cables and connections.