Manuals
/
Brands
/
Computer Equipment
/
Scanner
/
Fujitsu
/
Computer Equipment
/
Scanner
Fujitsu
600C manual
Please, tick the box below to download manual:
Contents
Main
Page
Table of Contents
Page
Page
Page
1. General
1.1 General
Page
Page
1.2.2 Components
2. Specifications
2.1 Functional Specifications 2.2 Environmental Specifications
2.1 Functional Specifications
2.2 Environmental Specifications
3. OPERATION
3.1 Removing the Shipping Bracket
Page
Page
3.4 Setting the SCSI ID and Connecting the Interface Cable
3.4.1 SCSI Cable Connection
Page
3.5 Paper Specifications
3.5.1 Paper Size
3.5.2 Paper conditions
3.5.2.1 ADF
3.5.2.2 FIatbed
3.5.2.3 Items to avoid
Page
3-10
3.6 Document Setting Method
3.6.1 Flatbed
Figure 3-6 Flatbed reading
3.6.1.1 When the document size is of letter/A4 size or smaller
3.6.2 ADF
3.6.2.2 Placing the documents on the ADF paper chute
Page
Page
3.7.2 Cleaning inside the ADF
Page
4. INTERFACE
4-2
Page
4.1.2 Physical Specification
4.1.3 Termination
4-5
4.1.4 Pin assignments
Note: Reserved pins are connected to GND. Figure 4-1Pin assignment
4-6
4.2 SCSI Bus
4.2.1 System configuration
4.2.1.1 System configuration
4.2.1.2 Addresses of SCSI devices
4.2.1.3 Peripheral equipment
4.2.2 Bus signals
Table 4-2 Bus signals
4-8
4.2.3 Bus signal drive conditions
Table 4-3 Bus phases vs. signal drive sources (1/2)
4.3 Bus Phases
}
4-10
Table 4-5 Signal delay times definition
4-11
Table 4.5 Signal delay times definition
4.3.1 BUS FREE phase
4-12
4.3.2 ARBITRATION phase
BSY SEL others
Page
4.3.3 SELECTION phase
4.3.4 INFORMATION TRANSFER phases
4.3.4.1 Asynchronous information transfer
Page
4.4 Commands
4.4.1 RESERVE UNIT command
4.4.1.1 RESERVE UNIT command: COMMAND phase (initiator target)
4.4.2 RELEASE UNIT command
4.4.2.1 RELEASE UNIT command: COMMAND phase (initiator target)
4.4.3 INQUIRY command
4.4.3.1 INQUIRY command: COMMAND phase (initiator target)
Page
4.4.3.2 Inquiry data: DATA IN phase (target initiator)
4-25
(l) sftRst (Soft Reset): Byte 7
(m) Vendor identification: Bytes 8 to F
(n)
4.4.4 REQUEST SENSE command
4. 4 .4 .1 REQUEST SENSE command: COMMAND phase (initiator
4.4.4.2 Sense data: DATA EN phase (target initiator)
Page
4-29
Table 4-13
4.4.5 SEND DIAGNOSTIC command
Table 4-14 SEND DIAGNOSTIC command
4. 4 .5 .1 SEND DIAGNOSTIC command: COMMAND phase (initiator
4-31
4.4.5.2 Contents of self-test
4.4.5.3 Results of self-test
4.4.6 TEST UNIT READY command
Table 4-15
4.4.6.1 TEST UNIT READY command: COMMAND phase (initiator target)
4.4.6.2 Acknowledgment
4.4.7 SET WINDOW command
4. 4 .7 .1 SET WINDOW command: COMMAND phase (initiator
4.4.7.2 Window date: DATA OUT phase (initiator target)
Page
Page
Page
Page
4.4.7.3 Update of ScanPartner 600C OEM manual
4.4.7.4 B&W Scanning Vender unique parameters
Page
4.4.7.5 Color Scanning Vender unique parameters
Page
4.4.8 OBJECT POSITION command
4.4.8.1 OBJECT POSITION command: COMMAND phase (initator target)
4.4.8.2 Acknowledgment
4.4.8.3 ADF sequence
4.4.9 READ command
4.4.9.1 READ command: COMMAND phase (initiator target)
4.4.9.2 DATA IN phase (target initiator)
4.4.10 Scan command
4.4.10.1 SCAN Command phase (initiator target)
4.5 Status: STATUS phase (target initiator)
4-51
4.6 Messages
4.6.1 ATN detection
Table 4-23
4.6.2 Message types
4.6.2.1 COMMAND COMPLETE (X'00'): MESSAGE IN phase (target initiator)
4.6.2.2 INITIATOR DETECTED ERROR (X'05'): MESSAGE OUT phase (initiator target)
4-53
Table 4-25 ATN detection phase Action SELECTION Moves to the BUS FREE phase
4.6.2.3 ABORT (X'06'): MESSAGE OUT phase (initiator target)
4.6.2.4 MESSAGE REJECT (X'07'): MESSAGE IN/OUT phase (initiator target)
4-54
Table 4-26
4.6.2.5 NO OPERATION (X'08'): MESSAGE OUT phase (initiator target)
4.6.2.6 MESSAGE PARITY ERROR (X'09'): MESSAGE OUT phase (initiator target)
Table 4-27
4.6.2.7 BUS DEVICE RESET (X'0C'): MESSAGE OUT phase (initiator target)
4.6.2.8 IDENDIFY (X'80' TO X'FF'): MESSAGE OUT phase (initiator target)
4.7 Command Sequence
4.7.1 Initial sequence
4.7.2 Read sequence
4.7.2.1 Read sequence for B&W mode
4.7.3 READ command sequence
4.7.3.1 Single READ
4.7.3.2 Multiple READ
4.8 Status Transition of Logical Unit
4.9 Error Table
4.10 Items for Specifying Window
: Cannot be specified
Page
5. Diagnostics
5.1 Online diagnostics
5.2 Offline diagnostics
5.3 Diagnostic flowcharts
5.3.1 Group 1 error flowchart (Lamp assembly)
5.3.2 Group 2 error flowchart (Flatbed/ADF motor)
5.3.3 Group 3 error flowchart (paper in ADF paper tray)
5.3.4 Group 3 error flowchart (no paper in ADF paper tray)