Fujitsu 600C c Window identifier Byte, d Auto Byte, f Upper left X,YULX, ULY Bytes 6 to 9, A to D

Models: 600C

1 95
Download 95 pages 10.46 Kb
Page 64
Image 64

(c)Window identifier: Byte 0

Specifies a unique value that identifies a window. The value may be 0 to 255. If two or more window identifiers are specified for a single set of window data, the most recently specified identifier is validated This scanner allows only one window to be set Therefore, only 0 may be specified in this field. II other than 0 is specified, this scanner returns the following error:

Status: B~0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(d)Auto: Byte 1

This scanner does not support auto. If a value other than 0 is specified, this scanner returns the foIl error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(e)X, Y resolution (XR, YR): Bytes 2 to 3 and 4 to 5

Specified here are the resolutions in the horizontal (X) and vertical (Y) scanning directions, in pixels per

inch. If 0 is specified, the default value (300 dpi) is assumed. The acceptable resolution value is as 60, 75, 80, 100, 120, 150, 200, 240, 300, 600. If a value is specified that does not comply with these conditions, this scanner returns the following error:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(f)Upper left X,Y(ULX, ULY): Bytes 6 to 9, A to D

Specified here are the X and Y coordinates of the upper-left comer of the window. The coordinates expressed in units of 1/1200 inches relative to the upper-left comer of the maximum scan area. If the ULX or ULY value is outside the maximum scan area of this scanner, this scanner returns the following error:

Status: B'00001'(CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

(g)Width, length (W, L): Bytes E to 11, 12 to 15

Specifies here are the width and length of the window, in units of 1/1200 inches. If the W or L value outside the maximum scan area of this scanner; the following error is returned:

Status: B'0000l' (CHECK CONDITION)

Sense key: X'5' (ILLEGAL REQUEST)

The same error is also returned if this scanner is set to less than one raster line for vertical scanning less than two bytes for horizontal scanning.

Notes:

1.ULX, ULY, W, L versus maximum scan area: 0< (ULX + W) ó 10200 (in 1/1200 inches)

0< (ULY + L) ó 13937 (in 1/1200 inches) for flatbed scan 0< (ULY + L) ó- 16800 (in 1/1200 inches) for ADF scan

2.Conditions for horizontal scanning: 9< {XR x W/1200] ó 5100

4-36

Page 64
Image 64
Fujitsu 600C manual c Window identifier Byte, d Auto Byte, e X, Y resolution XR, YR Bytes 2 to 3 and 4 to