4.4 Commands

BSY

SEL

C/D,MSG

I/O

REQ

ACK

DB

Bus settle

delay

 

deskew delay +

deskew delay +

cable skew delay

cable skew delay

4.4 Commands

Commands are directions issued from an initiator to a target. This image scanner supports the following range of the commands specified by the SCSI standard.

(a) The identification number of logical unit (LUN: logical unit number) is B'000.’

If this scanner receives a value other than 000, it returns an error as follows:

Status key: B'0000l’(CHECK CONDITION)

Sense key: X'5’(ILLEGAL REQUEST)

(b)Relative addressing is not supported.

If this scanner receives a relative address (RelAdr) =1, it returns an error as follows:

Status key: B'OOOOl’(CHECK CONDITION)

Sense key: X'5’(WLEGAL REQUEST)

(c)A control byte is not supported.

If this scanner receives a control byte X'00’, it returns an error as follows:

Status key: B'0000l ’(CHECK CONDITION)

Sense key: X'5’(ILLEGAL REQUEST)