(C)DO (device offline), UO (unit offline): Byte 1

This scanner ignores DO and UO.

(d)Parameter list length: Bytes 3 to 4

This scanner does not support parameter list length.

4.4.5.2Contents of self-test

The contents of self-test shall be an equivalent of NOP, provided that CHECK CONDITION is reported if err information is withheld in the unit.

4.4.5.3Results of self-test

This scanner reports the results of self-test as follows:

(a)Normal

The GOOD status is returned.

Status: B'00000' (GOOD)

Sense key: X'O' (NO SENSE).

(b)Abnormal

If error information is being withheld, the following status is returned:

Status: B'00001' (CHECK CONDITION)

Sense key: Error information being withheld

4.4.6TEST UNIT READY command

The following table shows the normal sequence of the TEST UNIT READY command when used with this scanner.

Table 4-15

Step

Bus phase

Initiator operation

←→

Target

 

 

 

 

operation

 

 

 

 

 

1

BUSFREE

Verifies bus free

 

 

2

ARBITRATION

Obtains bus-usage right

 

 

3

SELECTION

Select target

 

 

 

 

 

Drives BSY

 

 

 

 

signal

4

MESSAGE OUT

Selects logical unit

 

5

COMMAND

Specifies TEST UNIT READY (CDB)

 

6

STATUS

 

 

Reports GOOD

 

 

 

 

status

7

MESSAGE IN

 

Reports message

 

 

 

 

(Command

 

 

 

 

Complete)

 

 

 

 

Releases BSY

 

 

 

 

signal

8

BUS FREE

 

 

 

4-31

Page 59
Image 59