3Com 3C16897 8-slot DC Chassis, 3C16895 7-slot Chassis manual Type Y to run the primary image

Models: 3C16894 4-slot Chassis 3C16897 8-slot DC Chassis 3C16895 7-slot Chassis 3C16896 8 slot AC Chassis

1 80
Download 80 pages 5.46 Kb
Page 59
Image 59

Upgrading Software 59

The file you selected is SW7750-V300R-.app, are you sure? Yes or No(Y/N) y

On reboot,SW7750-V300R-.app will become the default application file to boot!

7Type Y to run the primary image:

Do you want to run snec400.app now? Yes or No(Y/N)? Y

No Backup Image If you do not enter the number of a backup boot file, the following text displays:

Please input the backup boot file number :

Input Error!

Failed to select backup image file!

Type Y to run the primary boot file:

Do you want to run snec400.app now? Yes or No(Y/N)? Y

Backup Image Fails If the backup image fails and another backup image configuration does not exist, the Switch 7750 will try to find any valid image on the flash. This image is not the primary or backup image:

All Images Fail If all images fail, the Switch 7750 will return to the boot menu:

primary image : snec400.app

 

backup image : SW7750-V300R-.app

 

There is one passed image in addition:

 

File Number

File Size(bytes)

File Name

========================================================

1.

6256229

SW7750-V300RE-8016.app

Press Ctrl+B to enter Boot Menu... 0

Auto-booting....................

Auto booting file is snec400.app

No LPU application file < vxworks.app > in flash

Please download LPU application file vxworks.app to flash

No correct main file to boot!

loading backup image file to boot!

Auto booting backup file is SW7750-V300R-.app

Page 59
Image 59
3Com 3C16897 8-slot DC Chassis, 3C16895 7-slot Chassis, 3C16894 4-slot Chassis manual Type Y to run the primary image