58CHAPTER 4: MAINTAINING SOFTWARE
Selecting the Application File for the Boot
If the Switch 7750 primary image fails because of a CRC error or a file format error, you can configure the system to find the backup image you select to boot from.
To select the image file that you want the system to boot from:
1Select 0 to return to the Boot Menu.
2Select option 2 from the Boot Menu. The following text displays:
File Number | File Size(bytes) | File Name |
======================================================== | ||
1. | 4 | snmpboots |
6256229 | ||
3. | 1012 | taskswitch.log |
4. | 151 | |
5. | 228308 | s.t |
6. | 1975 | sw7750.cfg |
7. | 631736 | Btm400.btm |
8(*). | 462848 | |
9. | 228376 | S3com400.app |
10. | 199696 | 8241btm.app |
11. | 2427 | vrpcfg.txt |
12. | 203460 | lpcom400.app |
13. | 228308 | snec400.app |
The current application file
The backup application file
Free Space : 7536640 bytes
3Enter the file number of the primary image:
Please input the primary image file number :13
4To confirm this choice, type Y at the prompt:
The primary file you selected is snec400.app, are you sure? Yes or
No(Y/N) Y
On reboot,snec400.app will become the default application file to boot!
5Enter the file number of the backup image:
Please input the backup image file number : 8
6To confirm this choice, type Y at the prompt: