APPENDICES SECTION APPENDIX C

Step 4: Rebuild the hard drive

Once the failed hard drive has been replaced, return to the Hardware Failure Detection screen in the Administrator console, and click Rebuild to proceed with the rebuild process.

WARNING: When the RAID array reconstruction process begins, the message “Enterprise Reporter Functionality Suspended, Drive Rebuild in Process” displays and the hard drive becomes inaccessible.

Step 5: Contact Technical Support

Contact Technical Support to order a new replacement hard drive and for instructions on returning your failed hard drive to 8e6.

Power supply failure

Step 1: Identify the failed power supply

The administrator of the server is alerted to a power supply failure on the chassis by an audible alarm and an amber power supply LED—or an unlit LED—on the front and rear of the chassis.

NOTE: A steady amber power supply LED also may indicate a disconnected or loose power supply cord. Verify that the power supply cord is plugged in completely before removing a power supply.

WARNING: Be sure the correct failed power supply has been identified. Removing the wrong power supply will cause the system to crash.

Step 2: Unplug the power cord

To prevent electrical shock to yourself and damage to the unit, unplug the power cord from the failed power supply.

138

8E6 TECHNOLOGIES, ENTERPRISE REPORTER ADMINISTRATOR USER GUIDE

Page 148
Image 148
8e6 Technologies ER manual Power supply failure, Rebuild the hard drive, Contact Technical Support, Unplug the power cord