7

Weight

The table below lists the weight of individual components used in the deployment of this system in third-party racks.

Item

Weight in kg

Weight in lbs

 

 

 

Fully configured system

13 kg

28.6 lbs

(with rack mount kit)

 

 

 

 

 

Rack mount kit

3.1 kg

6.82 lbs

 

 

 

CPU and heat sink

0.6 kg

1.32 lbs

 

 

 

Hard disk drive

1kg

2.2 lbs

 

 

 

Power supply module

1.3 kg

2.86 lbs

 

 

 

Floppy disk drive

0.16 kg

0.35 lbs

 

 

 

CD-ROM drive

0.3 kg

0.66 lbs

 

 

 

PCI card

0.04 ~ 0.4 kg

0.09 ~ 0.88 lbs

 

 

 

Power consumption

The server power supply is rated for a maximum 200W DC output. Maximum input AC power consumption is approximately 307W.

Using 110V AC power, a fully loaded system can consume up to 2.944A

Using 200V AC power, a fully loaded system can consume up to 1.619A

Deployment of ultra-dense 1U servers represent a significant power requirement. A simple formula to calculate server power requirements for an installation is:

(Number of servers) x (307W) = maximum power requirements for servers

Page 21
Image 21
Acer R300 manual Power consumption, Weight in kg Weight in lbs