S28

V.34 Modulation Enable/Disable

0= disabled, 1-255 = enabled, Range: 0-255

Default: 1

This register enables/disables V.34 modulation.

S30

Inactivity Timer

Range: 0-255

Default: 0

Units: minutes

S30 specifies the length of time (in minutes) that the modem will wait before discon- necting when no data is sent or received. This function is only applicable to buffer mode.

S32

Synthetic Ring Volume

Range: 0-255

Default: 10

This register specifies a synthetic ring volume in dB with an implied minus sign.

S33

Synthetic Ring Frequency

Range: 0-5

Default: 0

This register specifies a synthetic ring frequency. Valid ranges are 0-5, with 0= dis- abled and 1-5 corresponding to 5 ring frequencies.

S35

Data Calling Tone

0 = disabled, 1 = enableD Range: 0-1

Default: 0

Data Calling Tone is a tone of certain frequency and cadence as specified in V.25 which allows remote Data/FAX/Voice discrimination. The frequency is 1300 Hz with a cadence of .5 s on and 2 s off.